User's Manual

16 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide February 2008
4. Verify that the selected NEM has returned the expected feedback.
See “To Verify NEM Status” on page 17.
Using the ILOM Command-Line Interface
1. Log in to the ILOM CLI of the active Chassis Monitoring Module.
2. For a list of components in your system, type:
show /CH
3. If you installed a new NEM, go to Step 4.
When you were preparing a NEM for a hot-remove, if you corrected the problem
without removing the NEM or you decided not to remove the NEM, complete
the following steps:
a. Type this command to prepare a component for a hot-insert:
set /CH/component return_to_service_action=true
For example:
set /CH/NEM1 return_to_service_action=true
b. Use the show /CH/component command to list the status of the connection
from the NEM to each of the blades.
Note The following example depicts only the link status portion of the show
/CH/component command output.
-> show /CH/NEM1
blade0_link_status = Not_connected
blade1_link_status = Not_connected
blade2_link_status = Not_connected
blade3_link_status = Not_connected
blade4_link_status = Not_connected
blade5_link_status = Not_connected
blade6_link_status = Connected
blade7_link_status = Not_connected
blade8_link_status = Not_connected
fault_state = OK
clear_fault_action = (none)
prepare_to_remove_status = NotReady