FC PCI-Express HBA, Emulex Installation Guide
Chapter 1 HBA Overview 7
■ Brocade 200E switch
■ Brocade 300 switch
■ Brocade SW4100 switch
■ Brocade SW4900 switch
■ Brocade SW5000 switch
■ Brocade SW5100 switch
■ Brocade SW5300 switch
■ Brocade SW7500 switch
■ Cisco MDS9124 24-port multilayer fabric switch
■ Cisco MDS 9134 multilayer fabric switch
■ Cisco MDS 9140 multilayer fabric switch
■ Cisco MDS 9216A multilayer fabric switch
■ Cisco MDS 9216i multilayer fabric switch
■ Cisco MDS 9222i multiservice modular switch
■ Cisco MDS 9509 multilayer director
■ Cisco MDS 9513 multilayer director
■ McData Mi10K director
■ McData 6140 director
■ QLogic 9000
■ QLogic 5800
The HBA is supported by all 1-Gb Ethernet switches.
Environmental Requirements
The HBA environmental requirements are listed in TABLE 1-4.
TABLE 1-4 HBA Environmental Requirements
Specification Operating Non-Operating
Temperature 0˚ to 55˚C, non-condensing -40˚C to 70˚C, non-condensing
Airflow 150 lfm n/a
Humidity 10% to 90% RH, non-condensing, 27˚C max wet
bulb
93% RH, nonconducting, 38˚C max wet bulb