Sun StorageTek™ Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Installation and Basic Interoperability Guide Sun Microsystems, Inc. www.sun.com Part No. 819-5532-12 January 2007, Revision A Submit comments about this document at: http://www.sun.
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries.
Contents Preface 1. xi Product Overview 1 Single and Dual Port HBA Features 2 Minimum System Hardware Requirements Supported Operating Systems 2.
3. Hardware Installation 13 ▼ To Verify the Packaging Contents ▼ To Install the HBA Hardware ▼ To Attach the Optical Cable ▼ To Apply Power ▼ To Verify Proper Installation in SPARC Platforms ▼ To Verify the Attached Storage ▼ To Verify Proper Installation in x64 Based Systems Software Installation 14 16 18 Service Contact Information 4.
▼ To Create a Windows Boot Disk Service Contact Information A.
vi Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Figures FIGURE 3-1 Removing the Bracket Screws 15 FIGURE 3-2 Installing the Single and Dual Port HBAs FIGURE 3-3 Attaching the Optical Cable 16 17 vii
viii Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Tables TABLE 1-1 Single and Dual Port HBA Features TABLE 2-1 Sun Solaris 8, 9, and 10; Red Hat Enterprise Linux and SuSE Enterprise Linux; and Windows 2000 and Windows Server 2003 Host Platform Support 6 TABLE 3-1 Optical Cable Specifications TABLE 3-2 LED Indicator Status Definitions TABLE 3-3 20 TABLE 3-4 21 TABLE 4-1 Sun Solaris 8 and 9 Patches TABLE 4-2 Required Patches 2 17 18 27 29 ix
x Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex Host Bus Adapters Insallation and Basic In-
Preface This manual describes how to install, configure, and test the Sun StorageTek™ Enterprise PCI-X 4 Gb Fibre Channel (FC) Single or Dual Port Emulex Host Bus Adapter (HBA). This document is written for technicians, system administrators, authorized service providers (ASPs), and users who have advanced experience troubleshooting and replacing hardware.
Using UNIX Commands This document does not contain information about basic UNIX® commands and procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information: ■ Software documentation that you received with your system ■ Solaris™ Operating System documentation, which is at: http://docs.sun.
Typographic Conventions Typeface* Meaning Examples AaBbCc123 The names of commands, files, and directories; on-screen computer output Edit your.login file. Use ls -a to list all files. % You have mail. AaBbCc123 What you type, when contrasted with on-screen computer output % su Password: AaBbCc123 Book titles, new words or terms, words to be emphasized. Replace command-line variables with real names or values. Read Chapter 6 in the User’s Guide. These are called class options.
Documentation, Support, and Training Sun Function URL Documentation http://www.sun.com/documentation/ Support http://www.sun.com/support/ Training http://www.sun.com/training/ Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
CHAPTER 1 Product Overview This chapter provides a basic overview of the Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs).
Single and Dual Port HBA Features The single and dual port HBAs consist of a single-slot PCI-X 2.0 bus expansion board that interfaces a 64-bit PCI bus to one or two Fibre Channel (FC) optical media busses. The single and dual port HBAs support 32-bit and 64-bit PCI transfers as a master bus during direct memory access (DMA) transfers and 16-bit transfers as a slave during parallel input/output (PIO) operations, as well as PCI-X 1.0 and 2.0 transactions.
TABLE 1-1 Single and Dual Port HBA Features (Continued) Feature Description Maximum FC cable length 1 Gbps: 500 meters using 50/125 µm core fiber 300 meters using 62.5/125 µm core fiber 2 Gbps: 300 meters using 50/125 µm core fiber 150 meters using 62.5/125 µm core fiber 4 Gbps: 150 meters using 50/125 µm core fiber 70 meters using 62.
Supported Operating Systems You can use the single and dual port HBAs with the following operating systems: ■ Solaris 8, 9, and 10 Operating Systems To use the single and dual port HBAs with these operating systems, you must use the Sun driver as described in “Solaris 8, 9, and 10 Operating System Requirements” on page 8.
CHAPTER 2 Supported System Configurations This chapter describes the operating systems, host platforms, storage, and infrastructure configurations that support the Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs).
Basic Interoperability This section provides information about platform, storage, and switch compatibility permitting a heterogeneous Fibre Channel network design with the single and dual port HBAs. This section contains the following topics: ■ “Host Platform Support” on page 6 ■ “Storage System Support” on page 7 ■ “Fibre Channel Switch Support” on page 7 Host Platform Support The single and dual port HBAs are supported by the platforms and operating systems listed in TABLE 2-1.
Storage System Support The single and dual port HBAs support the storage systems are listed below.
Solaris 8, 9, and 10 Operating System Requirements This section contains information about using the single and dual port HBAs with the Solaris OS. Minimum Operating System Levels ■ Solaris 8 SPARC® OS Update 4/01 with the recommended patch cluster ■ Solaris 9 SPARC OS with the recommended patch cluster ■ Solaris 10 for SPARC and x64/x86 with the recommended patch cluster Note – Refer to your host platform documentation to determine minimum Solaris version required for your HBA installation.
Red Hat Enterprise Linux and SuSE Linux Enterprise Server Operating System Requirements This section contains information about using the single and dual port HBAs in Red Hat Enterprise Linux and SuSE Linux Enterprise operating systems.
Windows 2000 and Windows Server 2003 Operating System Requirements This section contains information about using the single and dual port HBAs in Windows 2000 and Windows Server 2003 operating systems. Minimum OS Levels ■ Windows 2000 ■ Windows Server 2003 Note – Refer to your host platform documentation and the Emulex web site to determine minimum Windows 2000 and Windows Server 2003 versions required. Known Issues and Bugs The following HBA issues exist at this time. ■ CR 6266132.
■ CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transport failure for a’timeout’ reason. Workaround: None at this time. A fix is being investigated. ■ CR 6352189. OBP probe gives unexpected output for unmapped channel / Sun StorEdge 3500 family arrays. This only occurs on the first probe-SCSI-all after a reset. Workaround: Perform another probe-scsi-all after a reset. The second try will yield correct results. A fix will be made available in the next FCode release after version 1.
12 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
CHAPTER 3 Hardware Installation This chapter provides instructions for installing the Sun StorageTek Enterprise PCI-X 4 Gb FC Single and Dual Port Emulex HBAs (henceforth referred to as single and dual port HBAs) in your system.
▼ To Verify the Packaging Contents ● ▼ Confirm that the single or dual port HBAs are shipped with the following items: ■ Sun StorageTek Enterprise PCI-X 4Gb FC Single or Dual Port Emulex HBA ■ Alternate PCI bracket ■ Accessing Documentation, 819-1209-xx To Install the HBA Hardware To install the single and dual port HBAs, you must open the system and identify an empty PCI or PCI-X slot. The single and dual port HBAs are keyed to prevent installation in +5.0-V signaling PCI slot types.
FIGURE 3-1 Removing the Bracket Screws b. Remove the bracket and store it for future use. c. Align the new mounting bracket tabs with the holes in the HBA. Note – Be careful not to push the bracket past the transceiver housing’s grounding tabs. Ensure that the LEDs are properly aligned with the holes in the bracket. d. Replace the screws that attach the HBA to the bracket. 6. Insert the HBA into the empty PCI or PCI-X slot. Press firmly until the adapter is seated. See FIGURE 3-2. 7.
FIGURE 3-2 Installing the Single and Dual Port HBAs Lever Screw Hole HBA retaining bracket HBA 64-bit PCI slot 32-bit PCI slot Slot covers System chassis Note – ▼ FIGURE 3-2 is a typical installation, which may differ from your installation. To Attach the Optical Cable Note – The single and dual port HBAs do not allow normal data transmission on an optical link unless it is connected to another similar or compatible Fibre Channel product (that is, multimode to multimode).
TABLE 3-1 Optical Cable Specifications Fiber-Optic Cable Maximum Length Minimum Length Connector 62.5/125 µm (multimode) 300 meters at 1.0625 Gbit/sec 150 meters at 2.125 Gbit/sec 70 meters at 4.25 Gbit/sec 2 meters LC 50/125 µm (multimode) 500 meters at 1.0625 Gbit/sec 300 meters at 2.125 Gbit/sec 150 meters at 4.25 Gbit/sec 2 meters LC Follow these steps when attaching the optical cable: 1. Connect the fiber-optic cable to an LC connector on the dual port HBA (see FIGURE 3-3).
▼ To Apply Power 1. Verify that the HBA is securely installed in the system. 2. Verify that the correct optical cable is attached. 3. Plug in and power on the system. 4. Observe the status of light-emitting diodes (LEDs) for the power-on self-test (POST) results as shown in TABLE 3-2. TABLE 3-2 summarizes LED indicator combinations. The LEDs can be seen through the openings in the HBA’s mounting bracket. Each port has a corresponding set of LEDs that provide a visual indication of the operating state.
TABLE 3-2 ▼ LED Indicator Status Definitions (Continued) Green LED Yellow LED State Slow Blink Flashing Restricted Offline Mode, test active Fast Blink Off Debug Monitor in Restricted Mode Fast Blink On Not defined Fast Blink Slow Blink Debug Monitor in Test Fixture Mode Fast Blink Fast Blink Debug Monitor in Remote Debug Mode Fast Blink Flashing Not defined To Verify Proper Installation in SPARC Platforms 1. Enter the show-devs command at the ok prompt to list the installed devices.
2. To positively identify the port as a Sun StorageTek 4 Gb FC port, access the SUNW,emlxs@N entries and enter .properties as shown in the example that follows. In this example, there is one Dual Channel SG-XPCI2FC-EM4-Z adapter installed: TABLE 3-3 {1} ok .
▼ To Verify the Attached Storage ● If online storage is connected to the HBA installed in a SPARC system, use the apply show-children command to list the attached storage. In the example that follows, a storage JBOD has twelve targets attached to one port of the dual-ported HBA.
▼ To Verify Proper Installation in x64 Based Systems ● Follow the instructions in the BIOS documentation provided with your system. Service Contact Information If you need help installing or using this product, call 1-800-USA-4SUN, or go to: http://www.sun.
CHAPTER 4 Software Installation After you have completed the hardware installation and powered on the computer, follow the instructions listed for your operating system to install the single and dual port HBA driver and any other utilities required for your installation. The following sections contain the instructions for installing software and the driver for the single and dual port HBAs.
Installing the HBA Driver With Solaris Operating Systems You must first install the latest available patch clusters for your Solaris OS. This section contains the following topics: ▼ ■ “To Download Solaris Patch Clusters” on page 24 ■ “Downloading HBA Driver Packages and Patches for Solaris 8 and 9 for SPARC” on page 24 ■ “Downloading HBA Driver Packages and Patches for Solaris 10 for SPARC or x64/x86” on page 28 ■ “Diagnostic Support” on page 29 To Download Solaris Patch Clusters 1.
The packages and patches are available either bundled as a script posted in the Sun Download Center (SDLC), or as individual packages and patches. Sun recommends using the install_it script, see “To Run An install_it Script Installation” on page 25. To install the packages and patches manually, see “To Do A Manual Installation” on page 26. ▼ To Run An install_it Script Installation The packages and patches are available from the Sun Download Center (SDLC). 1. Go to http://www.sun.com/storage/san.
▼ To Do A Manual Installation Optionally, for Solaris 8 and 9, if you do not want to use the install_it script, install the driver by adding the following packages and then patches. Packages The packages are available from the Sun Download Center (SDLC). 1. Go to http://www.sun.com/storage/san. The Storage Area Networks (SAN) page displays. 2. Scroll to the bottom of the page and under Get the Software, click the “Sun StorEdge SAN 4.4 release Software/Firmware Upgrades and Documentation” link.
1. Go to http://sunsolve.sun.com. The SunSolve Online license agreement page displays. 2. Accept the License Agreement. The SunSolve Online page displays. 3. Under Patches and Updates, click PatchFinder. 4. Download the appropriate patches for your system from TABLE 4-1. Type each patch ID (one at a time, and without the dash number) in the Enter Patch ID box and click Find Patch. 5. Follow the instructions in the patch README to install each patch. The patches must be installed in the order shown. 6.
Downloading HBA Driver Packages and Patches for Solaris 10 for SPARC or x64/x86 There is no install_it script available to install the drivers for Solaris 10. If you are using the Sun Solaris OS 10 01/06 or a later release, only the patch is required. Otherwise, you must first install the packages and then the patch. Note – The packages and patches must be installed in the order given. ▼ To Download the Packages Perform the following steps to download the Solaris 10 packages. 1. Go to http://www.sun.
▼ To Download the Patches Perform the following steps to download the Solaris 10 patches. 1. Go to http://sunsolve.sun.com. The SunSolve Online license agreement page displays. 2. Accept the License Agreement. The SunSolve Online page displays. 3. Under Patches and Updates, click PatchFinder. 4. Download one of the following patches by typing the patch ID (without the dash number) in the Enter Patch ID box and click Find Patch. ■ 120222-08 (or above) Sun OS 5.
Installing the HBA Driver With Red Hat and SuSE Operating Systems The Red Hat Enterprise Linux (RHEL) 3 and 4 and the SuSE Linux Enterprise Server (SLES) 8 and 9 operating systems are supported on the single and dual port HBAs. Before installing the drivers for Linux, you must have the relevant Linux OS installed on your hard disk. The driver and utilities are available for download at the Emulex web page dedicated to Sun products, the driver as a .gz package and the utilities as a .tar file.
Red Hat and SuSE OS Diagnostic Support Diagnostic support is provided by the Emulex lputil and HBAnyware utilities. They support the following functions: ■ List adapters ■ Adapter information ■ Firmware maintenance ■ Reset adapters To verify the installation, follow the instructions provided in the “View HBA Information using lputil” section of the Emulex Driver manual. Creating a Linux Boot Disk Emulex adapters enable you to load and boot the Linux operating system from a SAN-attached drive.
Installing the HBA Driver With Windows 2000 or Windows Server 2003 Operating Systems The Windows 2000 and Windows Server 2003 operating systems are supported on the single and dual port HBAs. Before installing the drivers for Windows, you must have the relevant Windows OS installed on your hard disk. The driver kit, which includes utilities, is available for download as a self-extracting .exe file at the Emulex web page dedicated to Sun products.
▼ To Install the Diagnostic and Management Utilities Diagnostic support is provided by the Emulex lputil and HBAnyware utilities. They support the following functions: ■ List adapters ■ Adapter information ■ Firmware maintenance ■ Reset adapters To verify the installation, follow the instructions provided in the “View HBA Information using lputil” section of the Emulex Driver manual. ▼ To Create a Windows Boot Disk 1. Go to http://www.emulex.com/ts/docoem/framsun/10k.htm.
34 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
APPENDIX A Declaration of Conformity, Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorageTek Enterprise 4 Gb Fibre Channel Single and Dual Port Host Bus Adapter: ■ “Declaration of Conformity” on page 37 ■ “Regulatory Compliance Statements” on page 39 ■ “Safety Agency Compliance Statement” on page 43 35
36 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Declaration of Conformity Compliance Model Number: Product Family Name: LP-XXXXX Sun StorageTek Enterprise PCI-X 4 Gb Fibre Channel Single and Dual Port Emulex HBA (SG-XPCI1FC-EM4-Z, SG-XPCI2FC-EM4-Z) EMC USA—FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This equipment may not cause harmful interference. 2. This equipment must accept any interference that may cause undesired operation.
/S/ Dennis P. Symanski Worldwide, Compliance Engineering Sun Microsystems, Inc. 4150 Network Circle, MPK15-102 Santa Clara, CA 95054 U.S.A. Tel: 650-786-3255 Fax: 650-786-3723 38 DATE /S/ Donald Cameron DATE Program Manager/Customer Quality Sun Microsystems Scotland, Limited Blackness Road, Phase I, Main Bldg.
Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Voluntary Control Council for Interference (VCCI) — Japan • Bureau of Standards Metrology and Inspection (BSMI) — Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product.
ICES-003 Class A Notice - Avis NMB-003, Classe A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. ICES-003 Class A Notice - Avis NMB-003, Classe A Parts This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label.
42 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBA Installation & Interop Guide • January 2007
Safety Agency Compliance Statement Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product. Depending on the type of power switch your device has, one of the following symbols may be used: On – Applies AC power to the system. Off – Removes AC power from the system.
Power Cord Connection Caution – Sun products are designed to work with power systems having a grounded neutral (grounded return for DC-powered products). To reduce the risk of electric shock, do not plug Sun products into any other type of power system. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building. Caution – Not all power cords have the same current ratings.
Rack System Warning CD and DVD Devices The following warnings apply to Racks and Rack Mounted systems. The following caution applies to CD, DVD, and other optical devices. Caution – For safety, equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc. Caution – To prevent the rack from tipping during equipment installation, the anti-tilt bar on the rack must be deployed.
Symboles Vous trouverez ci-dessous la signification des différents symboles utilisés: Attention – Vous risquez d'endommager le matériel ou de vous blesser. Veuillez suivre les instructions. Attention – Surfaces brûlantes. Evitez tout contact. Les surfaces sont brûlantes. Vous risquez de vous blesser si vous les touchez. Positionnement d’un produit Sun Attention – Evitez d'obstruer ou de recouvrir les orifices de votre produit Sun.
Attention – Tous les cordons d'alimentation ne présentent pas les mêmes caractéristiques électriques. Les cordons d'alimentation à usage domestique ne sont pas protégés contre les surtensions et ne sont pas conçus pour être utilisés avec des ordinateurs. N'utilisez jamais de cordon d'alimentation à usage domestique avec les produits Sun.
Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirez la barre anti-basculement du rack. Attention – Pour éviter des températures de fonctionnement extrêmes dans le rack, assurez-vous que la température maximale ne dépasse pas la fourchette de températures ambiantes du produit déterminée par le fabricant.
Je nach Netzschaltertyp an Ihrem Gerät kann eines der folgenden Symbole verwendet werden: Lautstärke Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling: Ein – Versorgt das System mit Wechselstrom. Measure and Environment Aus– Unterbricht die Wechselstromzufuhr zum Gerät. Wartezustand – Der Ein-/Standby-Netzschalter befindet sich in der Standby-Position. LwAd (1B = 10 dB) at or below 25ºC 8.0 B at max ambient 8.
Die folgende Warnung gilt nur für Geräte mit StandbyNetzschalter: Achtung – Beim Netzschalter dieses Geräts handelt es sich nur um einen Ein/StandbySchalter. Zum völligen Abtrennen des Systems von der Stromversorgung dient hauptsächlich das Netzkabel. Stellen Sie sicher, dass das Netzkabel an eine frei zugängliche geerdete Steckdose in der Nähe des Systems angeschlossen ist. Schließen Sie das Stromkabel nicht an, wenn die Stromversorgung vom Systemchassis entfernt wurde.
Hinweis zur Laser-Konformität Sun-Produkte, die die Laser-Technologie verwenden, entsprechen den Laser-Anforderungen der Klasse 1. Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser Klasse 1 Precaución – Existe el riesgo de que se produzcan lesiones personales y daños en el equipo. Siga las instrucciones. Precaución – Superficie caliente. Evite todo contacto. Las superficies están calientes y pueden causar lesiones personales si se tocan. Precaución – Voltaje peligroso.
Nivel de ruido Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling: Measure and Environment LwAd (1B = 10 dB) at or below 25ºC 8.0 B at max ambient 8.4 B LpAm bystander at or below 25ºC 66 dB at max ambient 69 dB Cumplimiento de la normativa para instalaciones SELV Las condiciones de seguridad de las conexiones de entrada y salida cumplen los requisitos para instalaciones SELV (del inglés Safe Extra Low Voltage, voltaje bajo y seguro).
Cubierta de la unidad del sistema la utilización de láser Debe extraer la cubierta de la unidad del sistema informático Sun para instalar tarjetas, memoria o dispositivos de almacenamiento internos. Vuelva a colocar la cubierta antes de encender el sistema informático. Los productos Sun que utilizan tecnología láser cumplen los requisitos establecidos para los productos láser de clase 1.
Danmark Advarsel! – Litiumbatteri — Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren. Suomi Varoitus – Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.