Sun StorEdge™ PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 817-5827-13 January 2007, Revision A Submit comments about this document at: http://www.sun.
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries.
Contents Preface 1. v Installing, Connecting, and Testing the Host Adapter Features 2 Installing the Host Adapter 3 ▼ To Prepare for Hardware Installation ▼ To Install the Host Adapter Connecting the Host Adapter ▼ 4 7 8 To Connect SCSI Cable(s) From the Host Adapter to the Storage Device(s) 8 Testing the Host Adapter 9 ▼ To Test the Installation Using the probe-scsi-all Command ▼ To Test the Installation With the SunVTS Software Booting the Host Adapter A.
B. SCSI Symbols 16 Specifications 17 Physical Dimensions 17 Power Requirements 18 Performance Specifications 18 PCI Edge Connector Pin Definitions SCSI Connector Pin Definitions C.
Preface This Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide is intended for experienced system administrators. Before You Read This Book Before you install and use the Sun StorEdge™ PCI/PCI-X Dual Ultra320 SCSI host adapter as described in this manual, you must read and understand the documents listed in the following table.
How This Book Is Organized ■ Chapter 1 describes the Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter and explains how to install it on your system, connect it to a storage device, and test it. It also includes instructions on booting from a hard disk connected to the host adapter. ■ Appendix A provides general information and configuration rules about the host adapter. ■ Appendix B contains the specifications for the low-voltage differential (LVD) host adapter.
Typographic Conventions Typeface* Meaning Examples AaBbCc123 The names of commands, files, and directories; on-screen computer output Edit your.login file. Use ls -a to list all files. % You have mail. AaBbCc123 What you type, when contrasted with on-screen computer output % su Password: AaBbCc123 Book titles, new words or terms, words to be emphasized. Replace command-line variables with real names or values. Read Chapter 6 in the User’s Guide. These are called class options.
Accessing Sun Documentation You can view, print, or purchase a broad selection of Sun documentation, including localized versions, at: http://www.sun.com/documentation To access Solaris OS usage documents listed under “Using UNIX Commands” on page vi and the SunVTS™ software documents listed in “Before You Read This Book” on page v, go to docs.sun.com.
Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
x Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007
CHAPTER 1 Installing, Connecting, and Testing the Host Adapter This chapter describes the Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter and explains how to install it into a host, connect it to SCSI storage devices, test the installation, and boot from a disk drive connected to the host adapter. Note – If you are unfamiliar with Ultra320 SCSI configuration guidelines, read “Ultra320 SCSI Configuration” on page 13 before performing the procedures in this chapter.
Features The Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter is a dual-channel Ultra320 SCSI to PCI/PCI-X host adapter that provides two Ultra320 SCSI channels.
■ 512K bytes of Flash ROM for booting in a Sun SPARC or a Sun Solaris x86 OS processor-based host system ■ A 64-bit universal type board edge connector that provides: ■ ■ 64-bit, 133-MHz PCI-X interface compatibility 32-bit/64-bit PCI interface backwards compatibility Installing the Host Adapter Before you start, read these instructions, and also read the installation instructions in the documentation that applies to the storage device(s) to be connected to the host adapter.
▼ To Prepare for Hardware Installation 1. Read and observe the safety information at the back of this book. See“Safety Agency Compliance Statements” on page 27. 2. Install the Solaris 8 2/04 (minimum required version) operating system on the host. 3. Install the Solaris 8 2/04 (minimum required version) recommended patch cluster on the host. See the Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Release Notes for how to download and install the Solaris OS recommended patch cluster. 4.
Caution – Do not disconnect the power cord from the system or from the wall ! outlet. This connection provides the ground path necessary to safely remove and install the printed circuit boards and components without damaging them. 8. Choose a PCI-X (or PCI) slot for installing the host adapter. To maximize performance, use the host system’s 64-bit, 66/133-MHz PCI/PCI-X slot slot for installing the host adapter.
9. Unpack the host adapter. You should have the following items: ■ ■ Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter (Figure 1-1) Antistatic wrist strap Note – Leave the host adapter in the protective bag until you are ready to install it. J6 connector J4 connector PCI/PCI-X connector J2 (Channel A) J3 (Channel B) FIGURE 1-2 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter VHDCI Connectors The host adapter is shown in Figure 1-2.
▼ To Install the Host Adapter 1. Open the system. Refer to your system documentation for information about how to open the system. 2. Attach the wrist strap between your wrist and a metal part of the system chassis. 3. For systems with a standby-type power switch, disconnect the power cord. Standby-type power switches have a icon. The wrist strap between you and the chassis provides the ground path necessary to safely remove and install the printed circuit boards and components without damaging them. 4.
Connecting the Host Adapter Before you connect the host adapter to the storage device(s), do the following: ■ ■ ■ ▼ Refer to the release notes for the lists of supported cables and storage devices. Downloading the release notes is described in “To Access the Release Notes” on page viii. Refer to Appendix A, “Ultra320 SCSI Configuration” on page 13 for general information on configuration for Ultra320 SCSI devices.
Testing the Host Adapter You should test the host adapter installation using the probe-scsi-all command and, if the newly attached device is a disk array, with the SunVTS software. ▼ To Test the Installation Using the probe-scsiall Command 1. If you have disconnected the power cable, reconnect it. 2. Power on the connected storage device(s) and then power on the host. 3. Bring the system down to the ok prompt at run level 0.
▼ To Test the Installation With the SunVTS Software Use the the SunVTS software to test a disk on a newly-attached disk array, to verify that the host adapter is properly installed. For details about running the the SunVTS software, refer to the SunVTS 5.X User’s Guide and the SunVTS 5.X Test Reference Manual. 1. As superuser, open the SunVTS window. # /opt/SUNWvts/bin/sunvts 2. From the System Map, select a disk drive that is in an array connected to the host adapter. 3. Start the disk test. 4.
Booting the Host Adapter The Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter uses the mpt driver, which is included with the Solaris operating system beginning with the Solaris 8 2/04 OS release and the Solaris 9 4/04 OS release. This enables you to “warm” boot directly from a hard disk connected to the host adapter if that disk has at least the Solaris 8 2/04 OS release or the Solaris 9 4/04 OS release installed.
12 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007
APPENDIX A Ultra320 SCSI Configuration This appendix provides general information about Ultra320 SCSI configuration rules. The following topics are discussed: ■ ■ ■ ■ “Target Devices” on page 13 “Bus Length” on page 14 “Cabling and Termination” on page 15 “SCSI Symbols” on page 16 Target Devices For Ultra320 SCSI performance of up to 320 Mbytes/sec, there can be a maximum of 15 devices connected to each port on the host adapter.
Bus Length The maximum SCSI bus length is determined by the SCSI bus type (that is, the number of devices connected). Table A-1 shows the maximum SCSI bus lengths for Ultra320 SCSI with a 8/16-bit bus width. TABLE A-1 Bus Restrictions SCSI Type Peak MBytes /sec Single-Ended LVD Max Length* No. of Devices Max Length* No. of Devices Narrow 10 3 8 Wide 20 3 16 25 12 25 12 2 8 2 16 20 1.5 3 1.
Cabling and Termination Use the following cabling guidelines to ensure proper device cabling and termination. Cabling In order to maintain Ultra320 SCSI performance, all cables used must be Ultra320 SCSI compliant. Termination ■ ■ The SCSI bus must be correctly terminated at the end of the bus. Most Sun devices use auto-termination. See the documentation that came with the device. This host adapter has active terminators with an automatic means of enabling and disabling the termination.
SCSI Symbols One of the four following symbols is placed near a SCSI port to indicate which type of SCSI the port is using. The icon may appear alone or with descriptive text.
APPENDIX B Specifications The chapter contains the specifications for the low-voltage differential (LVD) Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter.
Power Requirements TABLE B-2 Power Requirements Voltage Maximum Current 5V ±5% 3A 3.3V ±9% 0.0A 12V ±5% 0.
PCI Edge Connector Pin Definitions TABLE B-4 PCI Edge Connector Pin Definitions J1B (Top) Pin Description Pin Description Pin Description Pin Description 1 -12V 25 +3.3V 49 GND 73 GND 2 TCK 26 C_BE3 50 KEYWAY 74 AD[55] 3 GND 27 AD23 51 KEYWAY 75 AD[53] 4 TDO 28 GND 52 AD08 76 GND 5 +5V 29 AD21 53 AD07 77 AD[51] 6 +5V 30 AD19 54 +3.3V 78 AD[49] 7 INTB 31 +3.3V 55 AD05 79 +5V/+3.
TABLE B-5 PCI Edge Connector Pin Definitions J1A (Bottom) Pin Description Pin Description Pin Description Pin Description 1 TRST 25 AD24 49 AD09 73 AD[56] 2 +12V 26 IDSEL 50 KEYWAY 74 AD[54] 3 TMS 27 +3.3V 51 KEYWAY 75 +5V/+3.3V 4 TDI 28 AD22 52 C_BE0 76 AD[52] 5 +5V 29 AD20 53 +3.3V 77 AD[50] 6 INTA 30 GND 54 AD06 78 GND 7 INTC 31 AD18 55 AD04 79 AD[48] 8 +5V 32 AD16 56 GND 80 AD[46] 9 RESERVED 33 +3.
SCSI Connector Pin Definitions 34 1 68 VHDCI Connector 35 34 1 68 35 Internal SCSI Connector FIGURE B-1 VHDCI and Internal SCSI Connectors TABLE B-6 SCSI Connector Pin Definitions Pin Description Pin Description Pin Description 1 +SD(12) 24 +RST 47 SD(6)- 2 +SD(13) 25 +MSG 48 SD(7)- 3 +SD(14) 26 +SEL 49 SDP- 4 +SD(15) 27 +C/D 50 Cable Sense (GND) 5 +SDP(1) 28 +REQ 51 TERMPWR 6 GND 29 +I/O 52 TERMPWR 7 +SD(0) 30 GND 53 OPEN 8 +SD(1) 31 +SD(8) 5
TABLE B-6 22 SCSI Connector Pin Definitions (Continued) Pin Description Pin Description Pin Description 18 TERMPWR 41 SD(0)- 64 GND 19 OPEN 42 SD(1)- 65 SD(8)- 20 +ATN 43 SD(2)- 66 SD(9)- 21 GND 44 SD(3)- 67 SD(10)- 22 +BSY 45 SD(4)- 68 SD(11)- 23 +ACK 46 SD(5)- Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007
APPENDIX C Declaration of Conformity, Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI host adapter: ■ ■ ■ “Declaration of Conformity” on page 24 “Regulatory Compliance Statements” on page 26 “Safety Agency Compliance Statements” on page 27 23
Declaration of Conformity Compliance Model Number: Product Family Name: LSI22320-SR Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter (SGXPCI2SCSILM320-Z) EMC USA - FCC Class B This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This equipment may not cause harmful interference. 2. This equipment must accept any interference that may cause undesired operation.
Appendix C Declaration of Conformity 25
Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • • • Federal Communications Commission (FCC) — USA Department of Communications (DOC) — Canada Voluntary Control Council for Interference (VCCI) — Japan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product. FCC Class A Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.
Safety Agency Compliance Statements Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product. Depending on the type of power switch your device has, one of the following symbols may be used: On – Applies AC power to the system. Off – Removes AC power from the system.
SELV Compliance Safety status of I/O connections comply to SELV requirements. Power Cord Connection Caution – Sun products are designed to work with power systems having a grounded neutral (grounded return for DC-powered products). To reduce the risk of electric shock, do not plug Sun products into any other type of power system. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building.
Rack System Warning CD and DVD Devices The following warnings apply to Racks and Rack Mounted systems. The following caution applies to CD, DVD, and other optical devices. Caution – For safety, equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc. Caution – To prevent the rack from tipping during equipment installation, the anti-tilt bar on the rack must be deployed.
Attention – Tensions dangereuses. Pour réduire les risques de décharge électrique et de danger physique, observez les consignes indiquées. Selon le type d'interrupteur marche/arrêt dont votre appareil est équipé, l'un des symboles suivants sera utilisé: Marche – Met le système sous tension alternative.
Mise en garde relative aux batteries Attention – Les batteries risquent d’exploser en cas de manipulation maladroite ou de remplacement incorrect. Pour les systèmes dont les batteries sont remplaçables, effectuez les remplacements uniquement selon le modèle du fabricant ou un modèle équivalent recommandé par le fabricant, conformément aux instructions fournies dans le manuel de service du système. N’essayez en aucun cas de démonter les batteries, ni de les recharger hors du système. Ne les jetez pas au feu.
Einhaltung sicherheitsbehördlicher Vorschriften Lesen Sie vor dem Ausführen von Arbeiten diesen Abschnitt. Im folgenden Text werden Sicherheitsvorkehrungen beschrieben, die Sie bei der Installation eines Sun Microsystems-Produkts beachten müssen. Je nach Netzschaltertyp an Ihrem Gerät kann eines der folgenden Symbole verwendet werden: Ein – Versorgt das System mit Wechselstrom.
Anschluss des Netzkabels Warnung bezüglich Batterien Achtung – Sun-Geräte sind für Stromversorgungssysteme mit einem geerdeten neutralen Leiter (geerdeter Rückleiter bei gleichstrombetriebenen Geräten) ausgelegt. Um die Gefahr von Stromschlägen zu vermeiden, schließen Sie das Gerät niemals an andere Stromversorgungssysteme an.
Position im Rack eingebaut werden, gefolgt von den Systemen, die an nächsthöherer Stelle eingebaut werden, usw. Achtung – Verwenden Sie beim Einbau den Kippschutz am Rack, um ein Umkippen zu vermeiden. Normativas de seguridad Lea esta sección antes de realizar cualquier operación. En ella se explican las medidas de seguridad que debe tomar al instalar un producto de Sun Microsystems.
En función del tipo de interruptor de alimentación del que disponga el dispositivo, se utilizará uno de los símbolos siguientes: Encendido – Suministra alimentación de CA al sistema. Apagado – Corta la alimentación de CA del sistema. Espera – El interruptor de encendido/espera está en la posición de espera.
La siguiente medida solamente se aplica a aquellos dispositivos que dispongan de varios cables de alimentación: Precaución – En los productos que cuentan con varios cables de alimentación, debe desconectar todos los cables de alimentación para cortar por completo la alimentación eléctrica del sistema. Advertencia sobre las baterías Precaución – Si las baterías no se manipulan o reemplazan correctamente, se corre el riesgo de que estallen.
Dispositivos de CD y DVD La siguiente medida se aplica a los dispositivos de CD y DVD, así como a otros dispositivos ópticos: Precaución – La utilización de controles, ajustes o procedimientos distintos a los aquí especificados puede dar lugar a niveles de radiación peligrosos. Nordic Lithium Battery Cautions Norge Advarsel – Litiumbatteri — Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
38 Sun StorEdge PCI/PCI-X Dual Ultra320 SCSI Host Adapter Installation Guide • January 2007