Outdoor Storage Troubleshooting Guide
Chapter 5 Troubleshooting the Fibre Channel (FC) Links 45
Sun Proprietary/Confidential: Internal Use Only
Verifying the Data Host
The following example shows an error in the A1 or B1 FC link, which can cause a
path to go offline in the multipathing software.
CODE EXAMPLE 5-1 luxadm(1M) Display
# /usr/sbin/luxadm display
/dev/rdsk/c6t29000060220041F96257354230303052d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/
c6t29000060220041F96257354230303052d0s2
 Status(Port A): O.K.
 Status(Port B): O.K.
 Vendor: SUN
 Product ID: SESS01
 WWN(Node): 2a000060220041f4
 WWN(Port A): 2b000060220041f4
 WWN(Port B): 2b000060220041f9
 Revision: 080C
 Serial Num: Unsupported
 Unformatted capacity: 102400.000 MBytes
 Write Cache: Enabled
 Read Cache: Enabled
 Minimum prefetch: 0x0
 Maximum prefetch: 0x0
 Device Type: Disk device
 Path(s):
 /dev/rdsk/c6t29000060220041F96257354230303052d0s2
 /devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw
 Controller /devices/pci@6,4000/SUNW,qlc@3/fp@0,0
 Device Address 2b000060220041f9,0
 Class primary
 State OFFLINE
 Controller /devices/pci@6,4000/SUNW,qlc@2/fp@0,0
 Device Address 2b000060220041f4,0
 Class primary
 State ONLINE
...