Product Manual

SUMPRO
®
Battery Back-Up
OPERATION MANUAL
Dated: 08/17/2016
Document Name: SUMPRO_100_OM
Page 7 of 12
Register your product at www.ionproducts.net
Reserve Power (total hours of operation)
Duty Cycle (% of time running)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 25 30
100
90
80
70
60
50
40
30
20
10
0
Performance curve results using a 3/4 HP pump with
a 7.5 FLA and (2) Metropolitan Power Plus model
31P-36 batteries.
Warranty IS voId If...
1. Power cord has been cut or the grounding
prong has been removed.
2. Unit has been used in an outdoor application.
3. Batteries not meeting the above specications
have been used.
4. Unit has been submerged in water.
5. Unit has been tampered with in any manner
not described in the above instructions.
6. Unit has been disassembled by the customer.
7. Unit has been applied to products exceeding
the maximum capacity of the Unit, i.e., a pump
other than the one supplied with the unit or
more than one pump.
8. Unit has been applied to the wrong voltage.
9. Any labels or cord tags have been removed.
replacIng BatterIeS
Wear full eye protection and protective clothing.
When replacing the batteries, use the same type and
size batteries. See battery requirements (Page 2).
CAUTION: The electrolyte is a dilute sulfuric
acid that is harmful to the skin and eyes. It is
electrically conductive and corrosive. The following
procedures should be observed:
Do not lay tools or metal objects on top of the
batteries
Use tools with insulated handles
1. Unplug the unit from the wall.
2. Follow the Installation Instructions found on
page 3 of this manual, starting with step 8 and
working back to step 1.
3. Remove and safely dispose of old batteries.
4. Install new batteries per the installation
instructions on page 3.
technIcal SpecIfIcatIonS
Model 100
A.C. Lower Voltage Limit 98 VAC ± 5V
Output Voltage with Full Load 85-135V ± 10V
Maximum Output Current 12 FLA
Battery Lower Voltage Limit 18.5V ± 0.3V
Main Output Frequency 60 Hz
Overload 125 ± 3% (With Auto
Reset Function)
Alarm Contact RJ11 Connection,
Normally Closed Dry
Contact
Alternative DC Inputs 24VDC, 20A max