User's Manual
SUMMIT FS848 SLAVE MODULE
Model No. 44-2196 11 of 13 22867 NW Bennett St., Suite 200
support@focussemi.com
Hillsboro, OR 97124
www.focussemi.com TEL (503) 615 7734
FAX: (503) 615 4432
© 2009 FOCUS Enhancements
3.4.1 Set the calibrated hex value in the register
Command:
radio txpwr 0 (Hex Number)
For the hex number, please refer to the table below calibrated values
for a particular channel. Every audio client device comes with its own
unique calibration table.
Example: If the DUT has to transmit at +8dBm at 5180
radio txpwr 0 24
In the above command “0” is the TPC setting and 24 is the appropriate hex
value from the attached calibration table.
Calibration Table
SN: 1
Channel Hex#
5180 24
5200 24
5220 24
5240 24
5745 2F
5765 30
5785 32
5805 34
5825 34