Instruction Manual
15 
A12 
Light/Alarm relay options 
0: Light 
1: Alarm 
0 
/ 
do1 
Door switch control options 
0: Door switch is disabled; 
1: Fan stops running when the door is 
open; 
2: Light is turned on/off when the door is 
open/closed; 
3: Fan stops running and light is turned 
on when the door is open. Light is 
turned off when the door is closed; 
4: When the door is open, it inputs as 
synchronous defrost signal, i.e. defrost 
starts. 
0 
/ 
do2 
Whether buzzer responds when 
the door is open? 
0: No 
1: Yes 
0 
/ 
do3 
Door switch alarm delay 
0-99min 
3 
min 
cd1 
Condenser sensor options 
0: Disable 
1: Enable 
0 
/ 
cd2 
High alarm temperature 
(condenser) 
30℃ ~90℃ 
55℃ 
℃/℉ 
86℉~ 194℉ 
cd3 
High alarm temperature 
differential (condenser) 
1℃ ~15℃ 
5℃ 
℃/℉ 
2℉~ 30℉ 
u1 
Celsius / Fahrenheit② 
00:℉ 
01 
/ 