Owners Manual
26
IMPORTANT:
After your outdoor oven is converted to natural gas, the working pressure for natural gas is
7-inche water column (WC). Gas pressure is affected by gas line size and the length of gas
line run from house. Follow the recommendations in the chart below.
From Ho use to Oven
Distance
Tubing Size
Up to 25 ft.
3/8 in. DIA
26 – 50 ft.
1/2 in. DIA
51 – 100 ft.
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
Over 101 ft.
3/4 in. DIA
Burner LP Gas Natural Gas
Main Burner
16,000 BTU / Hr
16,000 BTU / Hr
CAUTION:
If low flames or burner problems are observed after converting from LPG to NG, the natural
gas lines may not be large enough. Refer to the “From House to Oven” chart above for
natural gas supply line specifications. Please contact a plumber to assure proper pressure
at 7-inch water column.
DO NOT RETURN YOUR GRILL TO THE STORE.