Operating Guide
49
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
REPLACINGCOMPONENTS
Gaskets
1. Door
Thisunitcomeswitha¾”ropegasketinthechannelaroundthedooropeningthat
shouldbereplacedatleastonceeveryyear.Toreplacethedoorgasket(Part#AC‐
DGKHD),theoldgasketmustfirstberemovedentirely—priortoaddingthenew
adhesive,youmay
havetoscrapetheoldcementfromthechannel.Oncethe
cementandgaskethavebeenadded,thedoorshouldbeclosedandlatchedfor
twenty‐fourhourstoallowthecementtoharden.Seenextpageformoreinfo.
2. Window
Ifyouarereplacingthewindowgasket(Part#AC‐GGK),thenewgasketwillalready
haveadhesiveononeside.Removethepaperontheadhesivesideandplacethe
gasketaroundtheoutsideedgeoftheglass,centeredovertheedge.Foldthegasket
edgesoveronthe
glass,forminga“U”shape.
3.
CombustionBlower
TheCombustionBlowerGasket(Part#PU‐CBMG)shouldbereplacedwheneveryou
removeorcleantheCombusti onBlowerassembly.
Removethegasketwithaputtyknife,andinstallthenewgasketbyapplying
adhesivetotheblowerflangeandinstallingthenewgasket(instructionsand
adhesiveareprovided
withthegasket).
4. CombustionBlowerMotor
Thecombustionblowermotorgasket(Part#PU‐CBMG)generallydoesnotneed
replacement,asitisnotnormallyremovedfromtheunit.However,iftheexhaust
bloweriscleanedbyremovingonlythemotor,ratherthantheentireblower
assembly,thisgasketmustbeinspectedandreplacedasnecessary.
IMPROPERGASKETMAINTENANCE,INCLUDINGFAILURETOREPLACEGASKETS,
CANCAUSEAIRLEAKSRESULTINGINSMOKE‐BACKS.
ITISMANDATORYTOREPLACEGASKETSANNUALLY.