Gaskets
IMPORTANT: IMPROPER GASKET MAINTENANCE, INCLUDING FAILURE TO REPLACE
GASKETS, CAN CAUSE AIR LEAKS RESULTING IN SMOKE-BACKS.
This unit comes with a
1
/
2
ā rope gasket around the door that should be replaced at least every two
years. To replace the door gasket (Part # AC-DGKCPM), the old gasket must first be removed
entirely ā prior to adding the new adhesive, you may have to scrape the old cement from the door
channel. Once the cement and gasket have been added, the door should be closed and latched for
twenty-four hours to allow the cement to harden.
If you are replacing the window gasket (Part # AC-GGK), the new gasket will already have
adhesive on one side. Remove the paper on the adhesive side and place the gasket around the
outside edge of the glass, centered over the edge. Fold the gasket edges over on the glass forming
a āUā shape. You should also replace the Combustion Blower gasket (Part # PU-CBG) whenever you
remove or clean the Combustion Blower.
Finish
This new unit has been painted with High-Temperature Paint that should retain its original look
for years. If the unit should get wet and rust spots appear, the spots can be sanded with plain steel
wool and repainted. We recommend High-Temperature Spray Paint (Part # AC-MBSP), as others
may not adhere to the surface or withstand the high temperatures.
Glass
This unit has a ceramic glass (Part # AC-G20, comes with gasket) in the viewing door. Surface
scratches are acceptable, but if this glass becomes cracked in any area, the unit should be shut
down and the window replaced with this high-temperature ceramic glass.
If you have any questions or problems contact the Technical Support Department:
Technical Support Department
service@englanderstoves.com
P.O. Box 206 Parts Orders ONLY: 800-516-3636
Monroe, VA 24574 Questions: 800-245-6489 (Fax: 434-929-4810)
You may also order parts and options, view frequently asked questions and more, on our
Web Site:
www.englanderstoves.com