Use and Care Guide

18
SHUT-DOWN PROCEDURE
WARNING: NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE.
Refer to the following instructions:
Press the “OFF” touch pad to put the stove in the “Shut-Down” mode. There will be an
S D” in the Heat Range and Blower Speed windows while the unit is shutting down to verify this. At
this time the red light above the “OFF” pad will illuminate. When the “OFF” pad is touched the auger
will instantly stop feeding fuel to the auger tube, but the room air blower, exhaust blower and Stirrer
will continue to operate. When the internal temperature drops to 95 degrees the room air blower will
cease to operate, and when the internal temperature drops to 90 degrees the exhaust blower will
stop. The red light will then shut off and the entire stove will be shut down. The hotter the unit is
operating, the longer it will take for the stove to complete the Shut-Down cycle.
Note: The unit will exit the Shut-Down cycle if you press the “ON” button during Shut-Down
.
NOTE: If your unit overheats, the auger will stop feeding, "E3" will be displayed on the
control board and the unit will go into Shut-Down. If this happens you need to wait 45
minutes before trying to re-light the unit.