Use and Care Guide

13
OPERATING INSTRUCTIONS
CAUTION: DO NOT OPERATE WITH THE DOOR OPEN.
Do not burn trash (paper bags, etc.) in this unit.
This stove has an induced draft system and is designed to operate continuously, as frequent
shutdown is not required. The setting of the “Heat Range” touch pad will control the heat output
and the amount of fuel the unit will burn (see “Control Board” section).
NOTE: This stove is using solid fuel and will not restart automatically unless a thermostat is
installed. See page 26 – Thermostat instructions.
* NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you select.
START- UP PROCEDURES
SETTING THE STIRRER
Warning: Do not open the door on this unit if the Stirrer is still moving!
Bodily Injury can occur!
The Stirrer may be turned Off by pushing the “Air On” button on the bottom of the Control Panel,
and then pressing both Down
arrows on the “Blower Speed” and “Heat Range” until you see a “0” in
the Blower Speed window.
The Stirrer may be turned back On by pressing the “Air On” button on the bottom of the Control
Panel, and then pressing both Up
arrows on the “Blower Speed” and “Heat Range” until you see a
“1” in the Blower Speed window.
CAUTION: Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, diesel fuel or
any other flammable liquid to start the fire. Keep all combustible materials at a
safe distance from stove.
The Heat Range and Blower Speed will automatically be set to setting “5” (default setting during
start up) to ensure that proof of fire is detected. During the 20 minute start-up period the user can set
the controls to a desired heat setting and after the 20 minute start-up the unit will operate at that user
setting. When burning corn, start-up period is 30 minutes.
Stirrer
Ill
ustration
2
This lug must be in the upright
position when restarting the stove