5.3 Disassemble hot “L” and cold water valve “Q” assembly to prepare for next step’s installation. Unscrew the inside set screw
of knob ”D” anticlockwise by Allen wrench “O” and disassemble the Knob from hot and cold valve assembly .
5.4 Position hot valve body “L” onto left mounting hole, attach the rubber gasket “J” and fasten lock nut ”k” from underneath the
sink, fasten the lock nut ”K” to valve body “L” by hand and fasten the set screw by the Allen wrench to attach knob onto
cartridge stem. Repeat the same procedure for the right (cold valve assembly “L”).