Troubleshooting
FAULT SOLUTIONS
The UNIT wILL NOT SwITch ON Check - unit / power cable connections
- power cable fuses
The FOrwArd Speed IS NOT cOrrecT Check - connection on unit
- magnet / sensor distance
- correct rotation of the magnet
- sensor wire continuity (resistance 100Ω ± 10)
- 100m coecient
TONNAge cOUNTer reAdINg INcOrrecT Check - connection / machine
- working width
- forward speed
- fertiliser coecient
- shutter opening and closing
cALIbrATION TeST Check - calibration factor (T)
Repeat the test in static mode
ShUTTerS OpeN TO mAxImUm TheN TO mINImUm Check - tractor forward speed coecient.
- spreading width (24.00 beware of the decimal point)
The UNIT SwITcheS ON cOrrecTLy, bUT The
AcTUATOrS dO NOT mOve
Check - the fuses
AreA cOUNTer reAdINg INcOrrecT Check - connection / machine
- working width
- forward speed
FLOw rATe Check - programmed ow rate
- fertiliser coecient
- PTO speed 540 rpm
- spreading width
- tractor forward speed
- shutter opening/closing
- actuator travel
- tramlining