Quick set-up User Manual

3
DPB : QUICK-START GUIDE
Réf: 400 369 - 02 - GB / DIS
06/2009
MAIN menu
Shows if the electric
shutters are opened
or closed
Shows the type of fertiliser
Shows the electric
actuator position
Enables adjustment of rate
per hectare
5
5
PERFORM A RATE CALIBRATION TEST
W
W
H EN
H EN
U S I NG
U S I NG
TH E
TH E
BUCKETS
BUCKETS
.
.
- Press on , the cursor moves to calibra-
tion test.
- Confirm by pressing , the electric ac-
tuators are in position, from here, follow the
on-screen instructions.
- Press on « start »
- Engage the DPA and drive.
- Let the fertiliser flow.
Max capacity of buckets .
- Weigh the collected fertiliser.
- With the numeric keypad, enter the weight
and confirm with .
The T-factor has been updated and you are
now ready to work.
W
W
H EN
H EN
U S I NG
U S I NG
A
A
WEIGHBR I D G E
WEIGHBR I D G E
.
.
If you can weigh the machine, then weigh
it once.
- Perform the calibration test and spread over
an area (from 0.2 to x ha ), weigh the ma-
chine again and enter the exact weight of fer-
tiliser actually spread, confirm with .
- The T-factor has been updated and you are
now ready to work.
NB
:
If you know the "T factor" it is possible to select it
manually:
- Select the SET menu.
- Select
- Select using the
keys
- Enter the value using the numeric key pad
and confirm
If you notice a difference between the program-
med and actual rate/hectare the T factor can be
modified.
EXAMPLE:
Initially the T factor = 0.90 and the rate/ha = 400
kg/ha
if the application rate achieved = 380 kg/ha:
the difference = -5%
In this case the T factor can be adjusted:
New T factor = 0.9 - (0.9 x 0.5 %) = 0.86
5
5
4
4
Press to operate the TRIBORD and
select the right / left or both discs
for rate modulation
4
4
SET THE QUANTITY PER HA
- Use the numeric keypad
- Confirm with .