Datasheet
www.suco.de
24
0164
Diaphragm pressure switches 42 V with stainless steel body
Body made of stainless steel (1.4305 / AISI 303)
With M3 screw or spade terminals
Overpressure safe up to 600 bar
1)
AMP 6.3 x 0.8
tin-plated
46
only R 1/8
hex 24
12 9
36
only R 1/8
hex 24
12 9
R o H S
compliant
With male thread
Accessories see page 17
Setting range in bar
(tolerance in bar at
room temperature)
Thread Normally open (no) –› |: Normally closed (nc) –› :|
0164 Diaphragm pressure switches with screw terminals
0.1 – 1 (± 0.2)
R1/8 0164 401 12 X 001 0164 402 12 X 002
G1/4-E 0164 401 41 X 001 0164 402 41 X 002
R1/4 0164 401 46 X 001 0164 402 46 X 002
1 – 10 (± 0.5)
R1/8 0164 405 12 X 005 0164 406 12 X 006
G1/4-E 0164 405 41 X 005 0164 406 41 X 006
R1/4 0164 405 46 X 005 0164 406 46 X 006
10 – 20 (± 1.0)
R1/8 0164 409 12 X 009 0164 410 12 X 010
G1/4-E 0164 409 41 X 009 0164 410 41 X 010
R1/4 0164 409 46 X 009 0164 410 46 X 010
20 – 50 (± 2.0)
R1/8 0164 413 12 X 013 0164 414 12 X 014
G1/4-E 0164 413 41 X 013 0164 414 41 X 014
R1/4 0164 413 46 X 013 0164 414 46 X 014
0164 Diaphragm pressure switches with spade terminals
0.1 – 1 (± 0.2)
R1/8 0164 403 12 X 003 0164 404 12 X 004
G1/4-E 0164 403 41 X 003 0164 404 41 X 004
R1/4 0164 403 46 X 003 0164 404 46 X 004
1 – 10 (± 0.5)
R1/8 0164 407 12 X 007 0164 408 12 X 008
G1/4-E 0164 407 41 X 007 0164 408 41 X 008
R1/4 0164 407 46 X 007 0164 408 46 X 008
10 – 20 (± 1.0)
R1/8 0164 411 12 X 011 0164 412 12 X 012
G1/4-E 0164 411 41 X 011 0164 412 41 X 012
R1/4 0164 411 46 X 011 0164 412 46 X 012
20 – 50 (± 2.0)
R1/8 0164 415 12 X 015 0164 416 12 X 016
G1/4-E 0164 415 41 X 015 0164 416 41 X 016
R1/4 0164 415 46 X 015 0164 416 46 X 016
Diaphragm material
– areas of application
NBR
Hydraulic / machine oil, heating oil, air, nitrogen etc.
1
EPDM
Water, brake uid, ozone, acetylene, hydrogen etc.
2
FKM
Hydraulic uids (HFA, HFB, HFD), petrol/gasoline etc.
3
See page 16 for temperature ranges of diaphragm / seal materials
Order number:
0164 XXX XX X XXX
Our pressure switches are
also available with factory
pre-set switching points.
Ready-wired versions can be
found starting on page 38
following.
We offer other body
materials and connecting
threads upon request.
Other diaphragm materials
are available on request,
e.g. HNBR or silicone.
1)
Static pressure, dynamic pressures should be 30 to 50% lower. These values refer to the hydraulic or pneu-
matic part of the pressure switch.