Item Brochure
AMPLIFIERS
Input Impedance: 430k ohm +/- 1%
Output Impedance: 4-10 ohm
Amplification: 56 dB +/- 3%
Frequency Range: 100Hz to 1500Hz
Power: 2 AA dry cell batteries (1.5 V x 2)
Power Consumption: 20 mA Nominal (30-hour life)
Weight: 0.507 lb. (230 gm)
Size: 5.7” x 3” x 1.25”
(145mm x 30mm x 68mm)
HEADPHONES
Impedance: 20 ohms
ABS CARRYING CASE
Weight (full): 5.84 lbs (2.65 Kg)
Size: 14” x 10.5” x 6”
(356mm x 267mm x 152mm)
Compact amplifier (with mute switch) fits inside the palm of the user’s
hand. Press the mute switch (on/off) to activate the leak sounds in the
headphones, and then release the mute switch when moving the sensor
(protects your hearing!).
Designed for all of the water leak detection applications, including leak
surveys and leak pinpointing. Use the 3-point ground plate for pinpoint-
ing on streets and concrete slabs. Use the magnet base or the contact
rod for leak surveys at hydrants, valves, or meters.
Extremely compact and lightweight. The entire LD-7 inside its heavy
duty carrying case measures only 14 inches x 10 inches x 6 inches,
small enough to be stored behind the seat inside the cab of the truck.
5 High Frequency filters, 3 Low Frequency filters (plus Low filter OFF),
and 2 Notch filters (plus Notch filter OFF) to remove continuous interfer-
ing noises from A/C hum, motors, wind, etc.
Hard ABS plastic custom carrying case included.
LD-7 WATER LEAK DETECTOR
SubSurface Instruments, Inc.
⎥
1230 Flightway Drive, De Pere, WI. 54115
toll free: 855.422.6346
⎥
Website: www.ssilocators.com
⎥
email: info@ssilocators.com
KEY FEATURES
FEATURES
SPECIFICATIONS
1) Amplifier w/volume & mute switch
Sensor w/3 point ground plate
Magnet base
Stereo headphones
3 section contact rod
1
2
3
4
5
1
2
3
4
5
Includes:
ABS custom case
Instruction manual