To select the desired battery source setup for Software verSIonS 3.43 and Greater:
• Press and hold depressed the
power on Button.
• Pressing the
frequenCy Button will toggle through available configurations. Repeat pressing until 'batt' is displayed
in the LCD.
• Release the
power on Button. 'd-Cell' or 'li-ion' will be displayed on the LCD.
• Press the
frequenCy Button to toggle through the available battery options.
• Press the
power on Button to shut the unit off. This will save the selected option for availability during
normal operation.
The PL-VF operating modes, frequencies and other functions are user programmable and can be changed at anytime
through a quick selection process in the programming menu.
Remove the back cover
Un-lock A & B Connectors
Remove the Li-Ion tray's screws
Connect & Lock Connectors A & B
Screw the back cover back in place.
Lift the Li-Ion tray
Screw down the d-Cell tray
Changing preset funCtions, modes & freQuenCies