Product Manual

www.ssilocators.com
34
SERIES
To select the desired battery source setup for Software verSIonS 3.43 and Greater:
Press and hold depressed the
power on Button.
Pressing the
frequenCy Button will toggle through available configurations. Repeat pressing until 'batt' is displayed
in the LCD.
Release the
power on Button. 'd-Cell' or 'li-ion' will be displayed on the LCD.
Press the
frequenCy Button to toggle through the available battery options.
Press the
power on Button to shut the unit off. This will save the selected option for availability during
normal operation.
The PL-VF operating modes, frequencies and other functions are user programmable and can be changed at anytime
through a quick selection process in the programming menu.
Remove the back cover
Un-lock A & B Connectors
Remove the Li-Ion tray's screws
Connect & Lock Connectors A & B
Screw the back cover back in place.
Lift the Li-Ion tray
Screw down the d-Cell tray
Changing preset funCtions, modes & freQuenCies
transmitter
A
A
B
B