Product Manual
www.ssilocators.com
25
SERIES
ON/OFF Button
Turns the unit on and off.
REFERENCE Button
When pressed it stores the signal strength and sets the reference mode. The tone will beep more
rapidly as the a-frame detects a similar signal strength. Pressing the reference button again (after a
reference has been taken) will display the original reference reading for 2 seconds. Turn the unit off
and on to clear the reference.
DIRECTIONAL ARROW
After proper synchronization the arrows will direct the user to the fault. If the signal strength drops
completely off in the area between the ground rod and the fault, the arrows will not properly display
direction until the unit comes within range of the fault or ground rod.
SIGNAL STRENGTH
The Signal Strength is displayed in a value from 0 to 100. The closer to the ground rod and/or the
fault will result in the highest reading. The signal strength may drop completely off in the area between
the ground rod and the fault.
LOW BATTERY
The A-frame Locator will indicate low battery condition by displaying the Low Battery icon on the
LCD screen.
ON/OFF Button
Directional Arrow
Indicates direction of
fault.
Signal Strength
Displays absolute signal
strength from 0 to 99.
Reference
Stores and displays starting
signal strength when
pressed
Low Battery Indicator
the a-frame reCeiver Controls & indiCators
opTinal accessory