Product Manual
4
5
Connections
Direct Mode Connection.
External Power Connection.
With the optional 12 volts DC power
cables, the Transmitter can be powered
from a truck or a car 12 volts battery.
Transmitter LCD Display
The PL-2000 Transmitter displays the
following information:
To turn the TRANSMITTER ON, push the
Power ON/OFF. The sounds “Tick-Tack” are
repeated four times and indicate that the
Power Switch is ON.
Display Frequency:
Inductive Mode : 27kHz or 8kHz.
Direct Mode : 27kHz, 8kHz, 0.5kHz
or MIX. MIX means the simultaneous
output of 27kHz, 8kHz, and 0.5kHz.
Output Mode Display:
IND = Inductive Mode
DIR = Direct Connection Mode
Power Source Display:
= D Cell Battery Operation
= Car Battery Operation
Display of Output Power from 0 to 7
Display of the ground conductivity and
the strength of the current owing in the
Direct Mode.
• POOR means “poor ground
connectivity”
• means “signal level is good”
When the TRANSMITTER controls are not
operated in the ON condition for one hour,
the Automatic OFF Function turns OFF the
power.
OPERATION OF TRANSMITTEROPERATION OF TRANSMITTER
Automatic OFF Function
When the TRANSMITTER controls are not
operated in the ON condition for one hour,
the Automatic OFF Function turns OFF the
power.
How to cancel the Automatic
OFF Function
Normally the Automatic OFF Function is ac-
tivated, but to deactivate this function, push
the Frequency Selection Key and then push
the Power ON/OFF Key.
When the Automatic OFF Function is deac-
tivated, “CONTINUOUS” is displayed on the
Transmitter display.
Note: The transmitter operates in the
Automatic OFF mode every time you
turn it on. If you wish to operate in the
“Continuous” Mode, you must deac-
tivate the Automatic OFF mode each
time after the words “SUBSURFACE
PL-2000” are displayed.
6
7
A
B
C
D
E
SubSurface
PL–2000
kHz
L
L[ ]
POWER OFF
DIR.CABLE
DC12V
6
7
A B C
D E
CONTINUOUS
SubSurface
PL–2000