Design Guide
6 | Sub-Zero Customer Care 800.222.7820
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required.
If the unit will be connected to a home security system,
allow 36"
(914) of excess wiring for proper connection.
IMPORTANT NOTE: The electrical outlet must be posi-
tioned with the grounding prong to the right of the thinner
blades.
IMPORTANT NOTE: For outdoor model UC-24RO, a
ground fault circuit interrupter (GFCI) is required to reduce
the risk of electrical shock. A GFCI is not recommended for
use with other Undercounter models and may cause inter-
ruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
Electrical supply location
Undercounter Refrigeration
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location
Plumbing Requirements
MODEL UC-24CI
Installation must comply with all applicable plumbing
codes.
For Model UC-24CI, locate the water supply line within
the shaded area shown in the illustration below. Connect
the water supply line to the house supply with an easily
accessible shut-o valve between the supply and the
unit. Do not use self-piercing valves. A saddle valve kit is
avail able through an authorized Sub-Zero dealer. For local
dealer information, visit the find a showroom section of
our website, subzero.com.
IMPORTANT NOTE: A reverse osmosis system can be used
provided there is constant water pressure supplied to the
unit at all times as indicated in the chart below. A copper
line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply ⁄" OD copper, braided stainless
steel, or PEX tubing
Pressure 20–100 psi (1.4–6.9 bar)
Excess Line for Connection 36" (914)