User Guide
Run a 120 V AC, 15 amp circuit (minimum)
power cable from the service panel to the
electrical box in the rough-in plate.
Remove the knockout and install the
conduit connector on the rough-in plate
hole. Refer to the illustration below for
wiring location.
Insert the conduit through the hole on top
of the rough-in plate to the electrical box.
Remove the electrical box cover from the
rough-in plate. Connect black wire to power
supply black wire, white wire to power
supply white wire and green wire to green
wire or bare wire.
Place all wiring connections inside the elec-
trical box and reinstall on the rough-in
plate. Make sure that the wires are secure
and that no wires are pinched between the
cover and box.
Refer to the wiring diagram packaged with the
hood liner for more information.
10
WOLF PRO VENTILATION HOOD LINERS
INSTALL WIRING
This ventilation hood liner must be
properly grounded and should be installed
by a qualified electrician in accordance
with all applicable national and local
electrical codes.
Before servicing or cleaning, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
2
1
/2
" (64)
2" (51)
2
1
/2
" (64)
Pro hood liner wiring location
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.