Design Guide
68 
|
 Sub-Zero Customer Care 800.222.7820
ELECTRICAL LOCATION—INTEGRATED
A
18" Model 6" (152)
24" Model 9
1
/2" (241)
30" Model 12
1
/2" (318)
WINE STORAGE
Electrical
The electrical supply must be located within the shaded 
area shown in the illustration for your specic model. For 
integrated (IW) models, also refer to the chart. A separate 
circuit, servicing only this appliance is required. A ground 
fault circuit interrupter (GFCI) is not recommended and may 
cause interruption of operation.
If the unit will be connected to a home security system, 
allow 36"
 (914) of excess wiring for proper connection.
IMPORTANT NOTE: For integrated (IW) models, the electrical 
outlet must be positioned with the grounding prong to the 
right of the thinner blades.
Installation must comply with all applicable electrical codes. 
ELECTRICAL REQUIREMENTS
Electrical Supply  115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
3" (76)
15
1
/2"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Model 424G, UW-24.
Model WS-30, BW-30.
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Integrated models.
UNDERCOUNTER WINE INTEGRATED PRO 48 BUILT-IN