6 Recharge the system with virgin R600a refrigerant.
Contaminated Sealed System
1 Always evacuate R600a refrigerant to the outdoors.
2 Use nitrogen for back-flushing the system.
3 Repair any leaks at the solder joint, or replace the defective
component.
4 Replace the compressor.
5 Replace the high-side filter drier.
6 Replace the evaporator or heat exchanger assembly if the
cap tube clogs.
7 Install a low-side drier on the suction line.
8 Recharge the system with virgin R600a refrigerant.
Sealed System Restriction
IMPORTANT NOTE: If a restriction is due to the sealed
system being contaminated, see Contaminated Sealed
System.
1 Always evacuate R600a refrigerant to the outdoors.
2 Locate and remove the restriction or locate and replace the
part.
3 Use nitrogen for back-flushing the system.
4 Replace the high-side filter drier.
5 Bump or tap the compressor to help release residual
refrigerant from the oil in the compressor.
6 Recharge the system with virgin R600a refrigerant.
Sealed System Refrigerant Overcharge
1 Always evacuate R600a refrigerant to the outdoors.
2 Use nitrogen for back-flushing the system.
3 Replace the high-side filter drier.
4 Bump or tap the compressor to help release residual
refrigerant from the oil in the compressor.
5 Recharge the system with virgin R600a refrigerant.