User Guide
8
33" (838)
RECOMMENDED
CABINET WIDTH
30-INCH OVEN OPENING
*Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop.
**Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
24" OR 30"*
(610 or 762)
TO COUNTERTOP
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
36"(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
28
3
/8" (721) COOKTOP
CUT-OUT WIDTH
1
5
/16" (49)
RADIUS
2
7
/16" (62)
19
3
/8" (492)
COOKTOP
CUT-OUT DEPTH
SEE COUNTERTOP
CUT-OUT BELOW
7
/16" (11) RADIUS
SEE COUNTERTOP
CUT-OUT BELOW
30
1
/8"*
(
765
)
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
FRONT OF COUNTERTOP
1
9
/16" (40)
21
1
/8"* (537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
*Minimum dimension, but may be exceeded by up to
1
/8" (3).
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
5
/16"
(
24
)
7
/8"
(22) max
COUNTERTOP
PROFILE
4" (102)
10"
(254)
3
1
/2" (89)
E
24"min
(610)
4"min (102)
13" max
(330)
Overall Dimensions
Countertop Cut-Out
21"
(533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
4" (102)
UNFRAMED MODEL CT30EU
The illustrations below provide the overall
dimensions, installation specifications and
c
ountertop cut-out for Model CT30EU.
F
or ease of installation, 33" (838) cabinets are
recommended for installation of Model CT30EU.
A Wolf 30" (762) built-in single oven may be
installed below Model CT30EU. For this installa-
tion, unless you are using cabinets deeper
than 24" (610), it is recommended that the
electrical supply be placed in the base cabinet
to the right of the oven. Refer to installation
instructions provided with the built-in oven for
additional specifications.
If Model CT30EU is installed above cabinets,
electrical placement is not critical. A grounded
e
lectrical box should be located within 4'
(1.2 m) of the right rear of the cooktop.
IMPORTANT NOTE:
Unframed electric
cooktop Model CT30EU is not designed to be
i
nstalled in combination with other cooktops.
IMPORTANT NOTE:
Unframed electric
cooktops cannot be installed with a downdraft
ventilation system.
For Model CT30EU installation options, refer to
Unframed Installations on pages 10–11.
MODEL CT30EU
Overall Width 30" (762)
Overall Height 4" (102)
Overall Depth 21" (533)
Minimum Cabinet Depth 22
3
/4" (578)
Minimum Height Clearance* 4" (102)
Cut-Out W
idth 28
3
/8" (721)
Cut-Out Depth 19
3
/8" (492)
*Minimum 6" (152) clearance is
r
equir
ed between counter
top and any
combustible sur
face dir
ectly below the
cooktop.
Dimensions may vary to
±
1
/8" (3).
INSTALLATION SPECIFICATIONS – MODEL CT30EU
WOLF