User Guide
5
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
Wolf electric cooktops are designed to fit a
standard 24" (610) deep base cabinet with a
2
5" (635) deep countertop. Before making the
countertop cut-out, verify that the cooktop will
clear the side walls of the base cabinet below.
For framed models, a minimum 5
1
/2" (140)
c
learance is required between the countertop
and any combustible surface directly below
the cooktop. For unframed models, a minimum
6" (152) clearance is required.
Refer to illustrations on the following pages for
installation specifications for each of the Wolf
electric cooktop models.
E
13
3
/8" (340)
CUT-OUT
WIDTH
4" (102)
FRONT OF COUNTERTOP
15"
(381)
15"
(381)
33" (838)
RECOMMENDED
CABINET WIDTH
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
13
3
/8" (340)
COOKTOP
CUT-OUT
WIDTH
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
13" max
(330)
18"
(457)
2"**
(51)
18"
(457)
2"**
(51)
24" OR 30"*
(610 or 762)
TO COUNTERTOP
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side. 18" (457) recommended cabinet width for installation of
single 15" (381) module. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop.
**Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop.
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
Overall Dimensions
Countertop Cut-Out
21"
(533)
OVERALL
DEPTH
15" (381)
OVERALL WIDTH
3
1
/2" (89)
MODEL CT15E
Overall Width 15" (381)
Overall Height 3
1
/2" (89)
Overall Depth 21" (533)
Minimum Cabinet Depth 22
3
/4" (578)
Minimum Height Clearance* 4" (102)
Cut-Out W
idth 13
3
/8" (340)
Cut-Out Depth 19
1
/4" (489)
*Minimum 5
1
/2" (140) clearance is
r
equir
ed between counter
top and any
combustible sur
face dir
ectly below the
cooktop.
Dimensions may vary to
±
1
/8" (3).
INSTALLATION SPECIFICATIONS – MODEL CT15E
FRAMED
MODEL CT15E
The illustrations below provide the overall
dimensions, installation specifications and
c
ountertop cut-out for Model CT15E.
I
f Model CT15E is installed above cabinets, the
electrical placement is not critical. A grounded
electrical box should be located within 4' (1.2 m)
o
f the right rear of the cooktop. For installation
above an oven, unless you are using cabinets
deeper than 24" (610), it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven.
IMPORTANT NOTE:
When multiple cooktops
and/or modules are installed side by side, refer
to countertop cut-out dimensions on page 12.