10  |  Sub-Zero Customer Care 800.222.7820
Alignment
LEVELING
Once the unit is in position, the height adjustment can be 
made from the front. Using a Phillips drive, turn clockwise 
to raise the unit or counterclockwise to lower. Use the 
lowest torque setting when using a power drill. Do not turn 
the leveling legs by hand. Refer to the illustration below.
When the unit is properly leveled, door/drawer adjust-
ments are less likely to be necessary.
IMPORTANT NOTE: Level the unit to the floor, not the sur-
rounding cabinetry. This could aect the operation of the 
unit, such as door closing.
 WARNING
To reduce the possibility of the unit tipping forward, 
the front leveling legs must be in contact with the 
floor.
Installation
Placement
 CAUTION
Before moving the unit into position, secure the door/ 
drawers closed and protect any finished flooring.
Use an appliance dolly to move the unit near the opening. 
The front leveling legs are extended below the front rollers 
to improve stability during placement. Once the unit is 
placed in front of the opening, completely retract the front 
leveling legs to allow the unit to be rolled into position. 
The front and rear leveling legs can be adjusted from the 
front once the unit is positioned.
If the unit has been on its back or side, it must stand 
upright for a minimum of 24 hours before connecting 
power.
Plug the power cord into the grounded outlet and roll the 
unit into position. Verify the anti-tip bracket is properly 
engaged.
REAR
ADJUSTMENT
FRONT
ADJUSTMENT