Design Guide
subzero.com | 67
Wine Storage
Plumbing Requirements
MODEL DET3050WCI
Installation must comply with all applicable plumbing 
codes.
For model DET3050WCI, locate the water supply line 
within the shaded area shown in the illustration below. 
Connect the water supply line to the house supply with an 
easily accessible shut-o valve. Do not use self-piercing 
valves. The water supply line must not interfere with 
installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is 
constant water pressure of 35–120 psi 
(2.4–8.3 bar) supplied 
to the unit at all times. A copper line is not recommended 
for this application.
WATER SUPPLY LOCATION A
DET3050WCI 6" (152)
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS 
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location
PLUMBING REQUIREMENTS
Water Supply   ⁄" OD copper, braided stainless 
steel, or PEX tubing
Pressure 35–120 psi (2.4–8.3 bar)
Excess Line for Connection 36" (914) 