Design Guide
subzero.com | 49
Designer Series Refrigeration
Electrical Requirements
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded 
area shown in the illustration and chart below. A separate 
circuit servicing only this appliance is required. 
IMPORTANT NOTE: For indoor models, a ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause 
interruption of operation. 
For the outdoor model, a ground fault circuit interrupter 
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply  115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
ELECTRICAL SUPPLY LOCATION A
18" Model 6" (152)
24" Model 9⁄" (241)
27" Model 11" (279)
30" Model 12⁄" (318)
36" Model 15⁄" (394)
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown 
in the illustration below. Connect the water supply line to 
the house supply with an easily accessible shut-o valve. 
Do not use self-piercing valves. The water supply line must 
not interfere with the installation of the anti-tip bracket.
Column and tall models with an ice maker or water dis-
penser feature a water filtration system. An in-line filter is 
required for drawer models with an ice maker when water 
conditions have a high sediment content.
A reverse osmosis system can be used provided there is 
constant water pressure of 35–120 psi 
(2.4–8.3 bar) supplied 
to the unit at all times. A copper line is not recommended 
for this application.
PLUMBING REQUIREMENTS
Water Supply Line  ⁄" OD copper, braided 
stainless steel, or PEX tubing
Water Pressure 35–120 psi (2.4–8.3 bar)
Excess Water Line for Connection 36" (914) 
WATER SUPPLY LOCATION A
18" Model 3" 
(76)
24" Model 5⁄" (140)
30" Model 6" (152)
36" Model 9" (229)
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS 
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location