Design Guide
subzero.com | 41
PRO Series Refrigeration
Electrical Requirements
Locate the electrical supply within the shaded area shown 
in the illustration below. A separate circuit servicing only 
this appliance is required. A ground fault circuit interrupter 
(GFCI) is not recommended and may cause interruption of 
operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply  115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Electrical supply location
Dual Installation
If two units are installed side by side, a dual installation kit 
may be required. Installations without a custom filler strip 
require a dual installation kit. If a dual installation kit is not 
specified, a 2" 
(51) filler strip is recommended between the 
units. Dual installations without a filler strip can only be 
accomplished using two units with opposite hinges. Refer 
to the illustrations below.
Dual installation kits are available through an authorized 
Sub-Zero dealer. For local dealer information, visit the 
find a showroom section of our website, subzero.com. 
For questions regarding the installation, call Sub-Zero 
Customer Care at 800-222-7820.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges
Same side hinges