subzero.com | 67
Wine Storage
Plumbing Requirements
MODEL DET3050WCI
Installation must comply with all applicable plumbing
codes.
For model DET3050WCI, locate the water supply line
within the shaded area shown in the illustration below.
Connect the water supply line to the house supply with an
easily accessible shut-o valve. Do not use self-piercing
valves. The water supply line must not interfere with
installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
WATER SUPPLY LOCATION A
DET3050WCI 6" (152)
3" (76)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
A
Water supply location
PLUMBING REQUIREMENTS
Water Supply ⁄" OD copper, braided stainless
steel, or PEX tubing
Pressure 35–120 psi (2.4–8.3 bar)
Excess Line for Connection 36" (914)