Extended Height Grill Installation
Extended Height Grille 6
Specify the customer-supplied hinging system consistent
with cabinetry and with sufcient capacity for the weight
of the decorative grille panel.
IMPORTANT NOTE: In the event that refrigeration com-
ponents must be removed for service, the standard grille
frame will need to be removed rst for sufcient access to
the machine compartment. To avoid an unsupported load,
the decorative panel will need to be removed from the
cabinetry rst.
Grille Hinging System
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN CLOSED
POSITION
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN FULLY
RAISED POSITION
GRILLE CLEARANCE
REQUIRED FOR SERVICE
CLEAT
CLEAT END VIEW
1
/
2
"
(13)
2" (51)
1
1
/
2
"
(38)
1
/2" (13) LIP
2" (51)
1
1
/2"
(38)
Field install a cleat to the back side of the decorative grille
panel to hold the ip-up inner grille frame in position when
it is raised. Follow dimensions in the inset illustration for
the 10"
(254) long cleat. For location of the cleat, also refer
to the illustration on the following page.
For a dual installation, use two cleats.
HINGING SYSTEM—INSTALL CLEAT
SIDE VIEW
The cleat must include a lip as shown, to prevent
unintentional separation of decorative grille panel and
grill frame.