Installation Guide
10 
|
 Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
WOOD FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening, 
drill pilot holes 
3
/16" (5) diameter maximum in the wall studs 
or wall plate. Use the #12 screws and washers to secure the 
brackets. Verify the screws penetrate through the ooring 
material and into wall studs or wall plate a minimum of 
3
/4" 
(19)
. Refer to the illustration below. 
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening, 
drill pilot holes 
3
/16" (5) diameter maximum in the wall studs 
or wall plate. Drill 
3
/8" (10) diameter holes into the concrete 
a minimum of 1
1
/2" (38) deep. Use the #12 screws and 
washers to secure the brackets to the wall, and use the 
3
/8" 
wedge anchors to secure the brackets to the oor. Verify 
the screws penetrate wall studs or wall plate a minimum of 
3
/4" (19). Refer to the illustration below.
4" (102)
MIN
24"
(610) 
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
4" (102)
MIN
24"
(610) 
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/2"(38)
min
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/2"(38)
MIN
Wood oor.
Concrete oor.
Anti-Tip Bracket
 WARNING
To prevent the unit from tipping forward, the anti-tip 
brackets must be installed.
The two anti-tip brackets must be installed exactly 24" 
(610)
 from the front of the opening to the back of the 
brackets and a minimum of 4"
 (102) from the sides of the 
opening. This depth will increase to 26
3
/16" (665) for a ush 
inset installation based on 
3
/4" (19) thick panels. Failure to 
properly position the anti-tip brackets will prevent proper 
engagement.
Use all anti-tip bracket hardware as instructed for wood or 
concrete oors.
IMPORTANT NOTE: For wood or concrete oor applications, 
if the #12 screws do not hit a wall stud or wall plate, use the 
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations the subooring or 
nished oor may necessitate angling the screws used to 
fasten the anti-tip brackets to the back wall.
ANTI-TIP HARDWARE
2 Anti-tip brackets
12 #12 x 2
1
/2" pan head screws
4
3
/8"–16 x 3
3
/4" wedge anchors
12 #12 at washers
4 #8–18 x 1
1
/4" truss head screws
4 Nylon Zip-it
®