Installation Guide
7
Lowes.com/
p
ortfolio
ASSEMBLY INSTRUCTIONS
6.
6
Outlet Box
AA
A
AA
AA
Wrap electrical tape (not included) around each
individual wire connector (AA) down to the wire. Push
wire connectors (AA) gently back into outlet box/wall.
Carefully push excess wiring into outlet box/wall.
WARNING: Make sure no bare wire or wire
strands are visible after making connections.
AA
5.
Unwrap BARE wire from BLACK and WHITE wires
on fixture (A). Prepare wires by stripping 3/4 in. of
insulation from wire ends using wire strippers (not
included). Connect WHITE wire from fixture (A) to
WHITE wire from outlet box/wall using existing wire
connector or wire connector (AA). Connect BLACK
wire from fixture (A) to BLACK wire from
outlet box/wall using existing wire connector or wire
connector (AA). Connect BARE/GREEN ground wire
from outlet box/wall to BARE ground wire from fixture
(A) with wire connector (AA).
NOTE: Screw wire connectors (AA) on in a clockwise
direction.
WARNING: Never connect BARE/GREEN
ground wire to WHITE or BLACK power supply wires.
WARNING: To reduce the risk of fire, electrical
shock or personal injury, wire connectors (AA) are
designed to accept only one 12-gauge house wire
and two lead wires from the light fixture. If your house
wire is larger than 12-gauge or there is more than
one house wire to connect to the corresponding
fixture lead wires, consult an electrician for the proper
size wire connectors to use.
Hardware Used
E3 Wire Connector
x 3
AA
Outlet Box
BLACK
BARE/
GREEN
AA
AA
5
WHITE
AA
AA
AA
A