Installation Guide
10
Sleeper Deck Systems
A sleeper system is a buffer between a solid surface and
Style Selections™ decking. Drainage, access and airflow are
critical. Water must be able to flow through and away from the
deck. For repairs and removal of debris, joist system access
is necessary. Good airflow will keep the decking dry and in
good condition.
Style Selections, when used with a sleeper system, must
be supported below its entire length and if used in a roofing
application, the supports must run the direction of the pitch
of the roof to facilitate proper drainage. In addition, sleeper
joists must be attached to the roof structure in a manner that
stabilizes the deck frame. Failure to do so may result in a poor
structure which will compromise deck performance.
In areas of application where a sleeper system is required
that would not be susceptible to excessive debris buildup
(examples would include covered areas such as balconies,
porches, etc.), a minimum height of 1-1/2 in (3.8 cm) for
pressure-treated joists as well as a minimum 1/4 in (0.6 cm)
gap between Style Selections decking would be acceptable.
These areas would still have to be designed to allow for
proper drainage and hidden fasteners would be acceptable.
However, if access to the structure under the decking is re-
quired, it would be recommended to use either the Universal
Fastener (plastic) or 2 in (5.1 cm) composite decking screws.
A 1/4 in (0.6 cm) to 1/2 in (1.3 cm) gap is still required when
abutting walls or other fixed objects.
In all other areas where there could be excessive water
buildup along with debris buildup, Style Selections would
recommend a minimum height of 3-1/2 in (8.9 cm) for pres-
sure-treated joists, as well as a gap of 3/8 in (1 cm). For this
application, hidden fasteners would not be recommended and
standard 3 in (7.6 cm) composite screws would be used.
ALWAYS consult your local building code authority for
proper details on roof and railing installation to the roof
structure if required.
ROOFTOP AND SLEEPER DECK SYSTEMS
DECKING
ROOFTOP DECK TIPS
° If you want to access the roof, you must build the
Style Selections deck in removable sections or with
removable fasteners.
° You must attach the sleeper joists to the roof structure
so that they stabilize the deck frame. Failure to do so
may result in a poor structure which will compromise
deck performance.