Installation Guide

7
Remove mounting plate (B) from canopy (D) by
removing mounting plate screws (C) from the
edges of the canopy (D).
Save mounting plate screws (C) for later use.
3.
3
C
D
C
ASSEMBLY INSTRUCTIONS
B
Attach mounting plate (B) to outlet box
(not included) using existing washers and
outlet box screws or the machine screws
(BB). NOTE: If the outlet box screws required
for your outlet box are of a different size than
the machine screws (BB), consult a licensed
electrician before proceeding.
Tighten machine screws (BB) completely to
secure mounting plate (B) to outlet box.
CAUTION: The fixture must be mounted
to an outlet box that is supported by the
building structure. Plastic outlet boxes are
not recommended.
4.
4
Hardware Used
Machine Screw
x 2
BB
Outlet
Box
BB
BB
B