StyleCrest Technical Specifications
3
SPECIFICATIONS
Electrical Supply - 120 volts, 60HZ, 1 Ph. Thermostat Circuit - 24 volts, 60HZ, 30 vac
Fuse or Breaker - 15 amps Normal Anticipator Setting - 0.4
Temperature Rise - 45° to 75°F Manifold Pressure - Natural Gas: 3.5” w.c. LP Gas: 10” w.c.
Gas Connection - 1/2" NFPT
High Altitude - Tables in the Installation Instructions for elevations above 2,000 feet.
Furnace
Model
No
Input Output Orifice Number ESP
in WC
Motor
HP
Motor
FLA
A / C
Ready
Tons
AFUE
%
Shipping Weight
Nat LP A
Cabinet
B
Cabinet
MG1E-056 56000 45000 29 45 0.3 3/4 8.4 4 80% 157 171
MG1E-070 70000 57000 24 42 0.3 3/4 8.4 4 80% 157 171
MG1E-077 77000 62000 21 40 0.3 3/4 8.4 4 80% 157 171
MG1E-090 85000 68000 17 36 0.3 3/4 8.4 4 80% 157 171
MODEL IDENTIFICATION CODE
Gas Furnace
Efficiency (AFUE)
E = 80.0%
H = 83.0%
J = 84.5%
P = 92.1%
R = 95.0%
S = 96.0%
M
1 056 F
1
Input Heating Capacity (BTU)
056 = 56,000
070 = 70,000
077 = 77,000
090 = 90,000
Series
Manufactured Housing
E
F = Front Return Downflow
T = Top Return Downflow
U = Upflow
A = 120V, 1 Phase, 60 Hz
G
A = No Evap Coil Cabinet
B = Cabinet fits 18' nominal coil heights
C = Cabint fits 24" nominal coil heights or smaller
A
B
1 = Single Stage
2 = Two Stage
1
Revision
M
Cabinet Width
M = Manufactured Housing
B = 17.5"
C = 21.0"