Brochure

Product Availability, Prices and Specications Subject to Change without Notice
Page 42
Revolv
®
RG7 95%
+
AFUE Gas Furnaces
Coil Cabinet
911969A ( 20" ) or 922594 ( 26" )
VENTING
All models are approved for both vertical and horizontal direct
(2 pipe) venting applications. See Vent Table below for
specied sizes and allowable lengths.
Maximum Direct Vent, Dual Pipe Length (ft.)*
RG7 Inputs (BTUH) Inlet / Outlet
3 in. Diameter
Inlet / Outlet
2 in. Diameter
45,000 60 30
60,000 60 30
72,000 60 30
*NOTES:
1. Subtract 3.5 ft. for each additional 3” 90 degree elbow.
2. Two 45 degree elbows are equivalent to one 90 degree elbow.
3. One short radius elbow is equivalent to two long radius elbows
4. Do not include termination elbows in calculation of vent length
5. This table is applicable for elevations from sea level to 2,000 ft.
For higher elevations decrease vent pipe lengths by 8% per
1000 ft. of altitude.
6. Only the listed pipe materials are approved for use with RG7
condensing furnaces.
7. For Canadian applications, use ULC S636 approved material.
RG7 95% GAS FURNACE SPECIFICATIONS
FURNACE
MODEL NUMBER
INPUT
KBTU/H
OUTPUT
KBTU/H
A/C
READY
TONS
RG7D45N4 45 42.75 4
RG7D60N4 60 57 4
RG7D72N4 72 68.4 4
RG7D45C4 45 42.75 4
RG7D60C4 60 57 4
RG7D72C4 72 68.4 4
CLEARANCES
ALL MODELS CLOSET ALCOVE
Front 1” 1”
Back 0 0”
Sides 0” 0”
Vent 0” 0”
Top 6” 6”
Duct (Plenum)
(w/coil box)
0” 0”
Duct (Plenum)
(w/o coil box)
within 3 feet
¼” ¼”
REVOLV RG7 95%
+
GAS FURNACES
MODEL NUMBER DESCRIPTION
SHIPPING WEIGHT
LBS
RG7D45N4 GAS95% DOWNFLOW 45KBTU NO CABINET 4 TON BLOWER
*
150
RG7D60N4 GAS95% DOWNFLOW 60KBTU NO CABINET 4 TON BLOWER
*
150
RG7D72N4 GAS95% DOWNFLOW 72KBTU NO CABINET 4 TON BLOWER
*
155
RG7D45C4 GAS95% DOWNFLOW 45KBTU W/CABINET 4 TON BLOWER 170
RG7D60C4 GAS95% DOWNFLOW 60KBTU W/CABINET 4 TON BLOWER 170
RG7D72C4 GAS95% DOWNFLOW 72KBTU W/CABINET 4 TON BLOWER 175
*
For cooling and heat pump applications , add coil cabinet 911969A ( 20" ) or 922594 ( 26" )