User Guide

Issue฀3,฀November฀2016฀ Model฀74/75฀User฀Guide฀
Page฀50฀ Studio฀Technologies,฀Inc.
for Surround
Function:฀Monitor฀Output฀Level฀-฀Reverse
Byte฀ Value฀ Description
1฀ F0H฀ System-Exclusive฀Message
2฀ 00H฀ 1
st
฀Byte฀of฀Studio฀Tech฀ID
3฀ 00H฀ 2
nd
฀Byte฀of฀Studio฀Tech฀ID
4฀ 56H฀ 3
rd
฀Byte฀of฀Studio฀Tech฀ID
5฀ 07H฀ Product฀ID฀(Model฀74)
6฀ 04H฀ Function,฀Monitor฀Output฀Level฀-฀Reverse
7฀ nnH฀ Monitor฀Output฀Level,฀MSB,฀range฀00-7F
8฀ 0nH฀ Monitor฀Output฀Level,฀LSB,฀range฀0-1
9฀ F7H฀ EOX,฀End฀of฀System-Exclusive฀Message
Notes: Not฀sent฀by฀control฀console.฀Provided฀for฀special฀applications.
Monitor฀output฀level฀is฀8-bit฀precision,฀spread฀over฀two฀MIDI฀bytes:฀00H฀00H฀highest;
7FH฀01H฀lowest.฀MIDI฀byte฀7฀is฀monitor฀output฀level฀bits฀2-8;฀MIDI฀byte฀8฀is฀monitor฀฀
output฀level฀bit฀1.
Dim฀function฀is฀performed฀by฀control฀console฀and฀is฀sent฀using฀monitor฀output฀level฀฀
command.