for Surround
Function:MonitorOutputLevel-Normal
Byte Value Description
1 F0H System-ExclusiveMessage
2 00H 1
st
ByteofStudioTechID
3 00H 2
nd
ByteofStudioTechID
4 56H 3
rd
ByteofStudioTechID
5 07H ProductID(Model74)
6 03H Function,MonitorOutputLevel-Normal
7 nnH MonitorOutputLevel,MSB,range00-7F
8 0nH MonitorOutputLevel,LSB,range0-1
9 F7H EOX,EndofSystem-ExclusiveMessage
Notes: Controlconsolesendsnewvalueeachtimemonitoroutputlevelischanged.
Monitoroutputlevelis8-bitprecision,spreadovertwoMIDIbytes:00H00Hlowest;
7FH01Hhighest.MIDIbyte7ismonitoroutputlevelbits2-8;MIDIbyte8is
monitoroutputlevelbit1.
Dimfunctionisperformedbycontrolconsoleandissentusingmonitoroutputlevel
command.