ACMainsPower
TheModel74isinternallyconfiguredto
operatefromanACmainspowersourceof
nominal100,120,or220/240volts,50/60
hertz.UnitsshippedtoNorthAmericaare
factoryselectedfor120voltoperation.
UnitsboundforJapanmustbeselectedfor
100volts,whileourfriends“downunder”
andinEuropereceiveunitssetfor220/240
volts.BeforeconnectingtheModel74to
ACmainspower,checkthatitisconfigured
tomatchthelocalmainsvoltage.Lookon
thebackpanel(adjacenttothepowerentry
connector)forthefactory-configuredvolt-
age.Notethatanincorrectconfiguration
couldpreventoperation,orcausedam-
agetotheunit.Shoulditbenecessaryto
changetheunit’soperatingvoltageitmust
beperformedonlyatthefactoryorbya
competentservicetechnician.
TheModel74usesanIEC-320C14-
compatibleconnectortomatewiththe
ACmainscord.ThewirecolorsintheAC
mainscordshouldconformtotheinterna-
tionallyrecognizedCEEcolorcodeand
mustbewiredaccordingly:
Connection WireColor
Neutral(N) LightBlue
Line(L) Brown
ProtectiveEarth(E) Green/Yellow
SafetyWarning:TheModel74does
notcontainanACmainsdisconnect
switch.Assuch,theACmainscord
plugservesasthedisconnectionde-
vice.Safetyconsiderationsrequirethat
theplugandassociatedoutletbeeas-
ilyaccessibletoallowrapiddisconnec-
tionofACmainspowershoulditprove
necessary.
AssoonasACmainspowerisapplied,the
Model74’spowerpresentLEDwillflashfor
afewseconds.Afterthecompletionofa
softwarestartupintervalthepowerpresent
LEDwilllightsteadily.ThedataactiveLED
ontheModel74willflashonceuponpow-
erup,thenbrieflylightuponcompletionof
theModel75’spower-upsequence.The
Model75willgothroughitsownpower-up
sequence,lightingeachLEDinsecession.
Configuration
Afterthephysicalinstallationhasbeen
completed,severalconfigurationissues
mustbeaddressed.OntheModel74the
surroundandstereoinputsmustbecali-
bratedusingthetrimpotentiometers.The
operatingparametersofthesystemshould
besetusingtheModel75ControlCon-
sole’sconfigurationmode.
LevelCalibration
Sixteen15-turntrimpotentiometersare
locatedonthefrontpaneloftheModel74
CentralController.Takingtimetocarefully
adjustthetrimpotswillensurethataccu-
ratemonitoringcantakeplace.Eachtrim
potallowsinputsignalswithanominallev-
elof–12dBVto+6dButobeutilized.With
care,it’seasytocalibratethesurroundand
stereoinputstowithinone-quarterofadB
ofthedesiredvalue.
Themonitoroutputsareusedasthe
measuringpointwhenadjustingthetrim
pots.Alaboratory-gradeaudiolevelme-
terorequivalentisrequiredforaccurate
calibration.Inaddition,theaudiosources
connectedtotheinputsmustbeableto
generatecontinuousaudiosignalsattheir
nominaloperatinglevel.