- Studer Sinewave Inverter, Battery charger User and Installer Manual COMPACT C1312COMPACT C1312COMPACT C1312COMPACT C1312 COMPACT C2324COMPACT C2324COMPACT C2324COMPACT C2324 COMPACT C3548COMPACT C3548COMPACT C3548COMPACT C3548
STUDER INNOTEC
COMPACT
COMPACTCOMPACT
COMPACT
User manual COMPACT V2.0 E 9
3.3.2 Protection cover for the terminals
connections
The protection is available in option (Order ref.
CFC-01) and avoid to do wrong hazardous
connection on the terminals 230Vac. It mounted
with strain relief clamps for the cable.
3.4 Connecting Plan / Front side
.
Caution: Check battery
polarity (+/-) before connecting!
A wrong connection could
damage the system.
16A-250Vac
BATTERY
SOLAR
Remote
control
Temp.
Don't open before
disconnect line
and battery
N
AC Input
AC Output
L
Equalize
Transfer delay
Auxiliary Contact
PE
N
L
PE
Remote
Power
sharing
C-2324
Ubat:
Pnom: 2300 VA
Uin: 150 - 250 Vac
N°:
Uout: 230 V/50 Hz
Typ:
22-32 Vdc
I Solar:
I Charge: 70A
30A max.
OM AL
B
C
D
EF G
HJ
K
N
A Battery +/- Battery cable (already installed)
B SOLAR +/- Connecting terminal for Solar modules
C Remote contr. Connecting terminal for Remote Control RCC-01
D Equalize Slide switch for equalization of the Battery
E Transfer delay Slide switch for Transfer Delay
F Temp. Connecting terminal for Temperature sensor CT-35
G Aux. Contact Connecting terminal for Auxiliary Contact
H AC Input Connecting terminal for AC-input. Located directly above this
terminal is the automatic safety cut-out for this terminal.
J ID Plate Identification plate with Technical data and Serial number