7 TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note: For information on other voltages/frequencies which are not shown, consult any
supplementary instruction sheet supplied, or the rating label attached to the
pump.
*Note: Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never exceed
65°C. A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimize deposition of scale in hard water areas.
Maximum permissible water temperature 65°C.
7.11 Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
Model U2.0 Single U3.0 Single U4.5 Single
Electrical
Power supply
Volts/phase freqency
230/1/50 230/1/50 230/1/50
Enclosure IPX4 IPX4 IPX4
Type of motor Induction Induction Induction
Power consumption 250 Watts 390 Watts 555 Watts
Full load current 1.1 Amps 1.7 Amps 2.5 Amps
Rating
Continuous (S1) @
9 l/min & above
Continuous (S1) @
9 l/min & above
Continuous (S1) @
9 l/min & above
Max. No Starts per hour 60 60 60
Mechanical
Max inlet head 8 metres 12 metres 12 metres
Max head (closed valve) 20 metres 32 metres 44 metres
Max working pressure* 600 kPa (6.0 bar) 600 kPa (6.0 bar) 600 kPa (6.0 bar)
Max ambient air temperature 40
o
C 40
o
C 40
o
C
Pressure vessel air pre-charge
90 kPa (0.9 bar)
(13 psi)
130 kPa (1.3 bar)
(18.5 psi)
130 kPa (1.3 bar)
(18.5 psi)
Max water temperature** 65
o
C 65
o
C 65
o
C
Min water temperature 4
o
C4
o
C4
o
C
Dimensions
Length 200 mm 200 mm 200 mm
Width 162 mm 162 mm 162 mm
Height (excluding flexible hoses) 243 mm 243 mm 243 mm