Owner manual

- 13 -
Cont ...
7 TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: Max working pressure is the maximum pressure that can be applied to
the pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never
exceed 65 °C. A stored water temperature of 60°C is considered
sufficient to meet all normal requirements and will minimise deposition of
scale in hard water areas.
7.11 Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
Model S1.4 bar
Electrical
Power supply
Volts/phase frequency
230/1/50
Enclosure IPX4
Type of motor Induction
Power consumption 445 Watts
Full load current 2.0 Amps
Rating Continuous (S1)
Max. No Starts per hour 60
Mechanical
Min inlet head 1 metres
Max inlet head 10 metres
Max head (closed valve) 14 metres
Max working pressure* 500 kPa (5.0 bar)
Max ambient air temperature 40
o
C
Max water temperature** 65
o
C
Min water temperature 4
o
C
Pump
Dimensions
Length (max) 273 mm
Width (max) 133 mm
Height (excluding flexible hoses) 264 mm
Weight (including accessories) 6.9 Kg
Pump Connections: Inlet G 1 Male
Outlet G 1 Male
Flexible Hoses G 1 Male x G 1 Female