7 TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: Max working pressure is the maximum pressure that can be applied to
the pump internal casing under any installation conditions.
7.11 Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
Model 2.6 bar PS 3.6 bar PS
Electrical
Power supply
Volts/phase frequency
230/1/50 230/1/50
Enclosure IPX5 IPX5
Type of motor Induction Induction
Power consumption 775 Watts 1136 Watts
Full load current 3.5 Amps 5.1 Amps
Rating Continuous (S1) Continuous (S1)
Max. No Starts per hour 60 60
Mechanical
Min inlet head 1 metres 1 metres
Max inlet head 10 metres 10 metres
Max head (closed valve) 26 metres 36 metres
Max working pressure* 600 kPa (6.0 bar) 900 kPa (9.0 bar)
Max ambient air temperature 40
o
C 40
o
C
Max water temperature 35
o
C 35
o
C
Min water temperature 4
o
C4
o
C
Cut out flow 1 l/min (approx) 1 l/min (approx)
Cut in pressure 180 kPa (1.8 bar) 180 kPa (1.8 bar)
Vessel charge 210 kPa (2.1 bar) 210 kPa (2.1 bar)
Pump
Dimensions
Length (max) 541 mm 541 mm
Width (max) 300 mm 300 mm
Height (excluding flexible hoses) 633 mm 633 mm
Gross Weight (including accessories) 17 Kg 18.5 Kg
Pump Connections: Inlet G 1 Male G 1 Male
Outlet G 1 Male G 1 Male