6 TECHNICAL SPECIFICATION
Electrical
Volts/Ph/Frequency 230/1/50
Power consumed 500 Watts
Full load current 2.2 Amps
Rating Continuous
Max. No Starts per hour 60
Enclosure IPX4
Fuse Size 5 Amps
Mechanical
Max flow 12 litres/min
Max head (closed valve) 32 metres
Max working pressure * 600 kPa (6 bar)
Max liquid temperature 35
o
C
Min liquid temperature 4
o
C
Max ambient air temperature 40
o
C
Max noise level 65 dB
Pump
Dimensions
Length 210 mm
Width 130 mm
Height 231 mm
Weight 5.2 Kg
Connections
Inlet / outlet G ¾ Male
Connecting cable 1.5 metres
Materials
Body Brass
Shaft Stainless Steel
Mechanical Seal Nitrile/carbon/ceramic
Pump Parts Brass
*Max working pressure is the maximum pressure that can be applied to the pump
internal casing under any installation condition.