User Manual

pg 34
blueSky - reverberator
Power Up Modes - Quick Reference
Global parameters and functions can be accessed via a power up proce-
dure� All power up functions persist through power cycles�
General Options
1 Press and hold the ON footswitch while powering up blueSky� Once
both LEDs flash, release the footswitch�
2 Adjust the desired functions with the knobs noted below
3 Press either footswitch to store your changes and exit power up mode�
INPUT LEVEL
See page 9
for an illustrated
description�
Turn the DECAY knob - status shown on the FAV LED
Instrument: GREEN (default)
Line: RED
BYPASS MODE
See page 10
for an illustrated
description�
Turn the MIX knob - status shown with the ON LED
True Bypass: GREEN (default)
Buffered Bypass: RED
SPILLOVER MODE
See page 11
for an illustrated
description�
Turn the LOW knob - status shown momentarily on both
LEDs
Off: AMBER (default)
ON: PURPLE
FACTORY RESET
See page 27
for an illustrated
description�
Turn PREDELAY knob from 0% to 100% and back two
times - status shown on FAV LED