Users Manual
Initialisation Device Charger
Instructions for Use
Copyright © 2020 STRYDE All rights reserved
6
charge the Initialisation Devices used by the crews during deployment and retrieval of the
seismic Nodes. Initialisation Devices shall be inspected for damage before charging, damaged
units shall be decommissioned when returned to the local operations hub. Initialisation Devices
should be clean and dry before charging with the Initialisation Device Charger.
The Initialisation Device Charger shall be powered by a single-phase mains supply which
powers the internal AC/DC power supply. The lid of the Initialisation Device Charger should
be lifted by the operator, up to 45 Initialisation Devices can be charged simultaneously by
locating them in the charging holes and closing the lid. Each Initialisation Device has a battery
management circuit that is used to start, stop, and regulate the charging rate. In addition,
there is a mechanical switch that can be used to switch the Initialisation Device Charger on and
off. The operator may briefly remove the lid to check the led indicator on the Initialisation
Devices: slow blink red means the unit is charging; a solid green means the unit is charged;
an occasional fast blink red LED mean the unit is fully charged and has entered low power
sleep mode. The charging time will take no more than 4 hours.
Charging shall be done away from flammable materials, and a fire extinguisher shall be
within reach for emergency use.
7. Installation
The Initialisation Device Charger shall be installed on a bench by trained personnel that are
familiar with the STRYDE system.
8. Storage and Maintenance
During deployment, the Initialisation Device Charger shall be stored on a bench in a clean air-
conditioned area, with the lid fitted to prevent the ingress of dust and dirt in the charging
holes.
When placed in a cardboard box for shipping the unit shall be protected with suitable
packaging material.
Regular maintenance of the Initialisation Device Charger in storage is not necessary.
9. Transportation
The Initialisation Device Charger shall be packed in a suitable box with protective packing
material to prevent damage in transit.
10. Faults and repair
Fault finding and repairs to the Initialisation Device Charger shall only be performed by
authorized service personnel who are familiar with the STRYDE system.